Shapley effects to identify the most influential input parameters of organ dose estimation following CT scans in childhood
Journal of Radiological Protection · 2026
DOI: 10.1088/1361-6498/aeb137 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Radiological Protection, 2026. Verfasst von Anaïs Foucault und 5 weiteren Autor:innen. Beteiligte Einrichtung: Autorité de Sûreté Nucléaire et de Radioprotection (ASNR), D2R/SERHEN/LEPID, Fontenay-aux-Roses, F-92260, France. Hauptthemen laut MEDLINE: Tomography, X-Ray Computed, Radiation Dosage, Radiometry. Die Arbeit nennt 50 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
A current methodological challenge in radiation epidemiology is to account for dose uncertainty in risk estimation. An important preliminary step can be to identify the most influential input parameters involved in dose estimation, before modelling and accounting for their related uncertainty in radiation-induced health risk estimates. In this work, a variance-based global sensitivity analysis (GSA) was performed with Shapley effects and, for the first time in radiation dosimetry, to rank by influence the input parameters of a software conventionally used to estimate organ doses arising from computed tomography (CT) scan exposure: NCICT (National Cancer Institute Dosimetry System for CT) (version 1.0). We focused on brain and red bone marrow (RBM) dose estimation in the French CT cohort and our GSA was performed for three types of examination, classified according to the scanned body region: head, chest, and abdominopelvic. Among the eight uncertain input parameters involved in dose estimation, different influential parameters were highlighted depending on both the scan type and the considered organ dose: these are consistent with the underlying dose calculation methodology. For head CT examinations, technical parameters used for image acquisition including x-ray tube current-time product (mAs) and tube potential (kVp), as well as the end of the scanned body area contributed to about 70% of the variance of the brain dose estimate, while mAs, kVp, the start and end of the scanned body area, and age influenced the RBM dose. The brain and RBM doses delivered during chest CT examinations were mainly influenced by mAs, pitch, and kVp. Finally, kVp was the only input parameter with a significant influence on both the RBM and the brain dose for abdominopelvic CT examinations: it explained more than 30% of the variance of these organ doses. From a clinical perspective, our findings may support optimisation of paediatric CT protocols.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Autorité de Sûreté Nucléaire et de Radioprotection (ASNR), D2R/SERHEN/LEPID, Fontenay-aux-Roses, F-92260, France.
- Département de Mathématiques, Université du Québec à Montréal, Montréal, QC, Canada.
- EDF Lab Chatou, 6 Quai Watier, 78401 Chatou, France.
- SINCLAIR AI Lab., Saclay, France.
- Division of Cancer Epidemiology and Genetics, National Cancer Institute, National Institutes of Health, Rockville, MD 20850, United States of America.
ORCID-Profile: Sophie Ancelet
Zitieren
APA
Foucault, A., Idrissi, M. I., Iooss, B., Lee, C., Bernier, M. O., & Ancelet, S. (2026). Shapley effects to identify the most influential input parameters of organ dose estimation following CT scans in childhood. Journal of Radiological Protection. https://doi.org/10.1088/1361-6498/aeb137
Vancouver
Foucault A, Idrissi MI, Iooss B, Lee C, Bernier MO, Ancelet S. Shapley effects to identify the most influential input parameters of organ dose estimation following CT scans in childhood. Journal of Radiological Protection. 2026. doi:10.1088/1361-6498/aeb137