EUVIMEDEUVIMED entdecken
Crossref

Gantry tilt as a dose reduction strategy for radiosensitive organs in pediatric brain CT: a prospective TLD study

Osman Vefa Gul iD, Mustafa Koplay, Mehmet Ozturk

Radiation Protection Dosimetry · 2026

DOI: 10.1093/rpd/ncaf144 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Radiation Protection Dosimetry, 2026. Verfasst von Osman Vefa Gul und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Oncology, Faculty of Medicine, Selcuk University, Konya 42130, Turkey. Hauptthemen laut MEDLINE: Brain, Thermoluminescent Dosimetry, Lens, Crystalline, Tomography, X-Ray Computed. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 39 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Brain computed tomography (CT) is commonly performed in pediatric patients; however, radiation exposure to radiosensitive organs such as the lens and thyroid remains a major concern. This prospective study investigated the impact of gantry tilt on organ doses using thermoluminescent dosemeters. A total of 67 pediatric patients undergoing brain CT were divided into four age groups: 0–18 months, 18 months–5 y, 5–10 y, and 10–17 y. In vivo lens and thyroid doses were measured with and without gantry tilt, and their correlation with volume CT dose index (CTDIvol) was assessed. Significant positive correlations were observed between CTDIvol and both lens and thyroid doses. With gantry tilt, mean lens doses were 2.19–5.73 mGy and thyroid doses 0.68–0.99 mGy, compared with 10.89–29.30 mGy and 1.29–3.72 mGy, respectively, without tilt. Gantry tilt parallel to the supraorbital–meatal baseline substantially reduced organ doses, particularly to the lens, and should be considered as a practical optimisation technique in pediatric neuroimaging.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

BrainThermoluminescent DosimetryLens, CrystallineTomography, X-Ray ComputedThyroid GlandRadiation ProtectionOrgans at RiskNeuroimagingHumansInfantChild, PreschoolProspective StudiesChildRadiation DosageMaleFemaleAdolescentInfant, NewbornRadiation Exposure

Autor:innen und Institutionen

  • Department of Radiation Oncology, Faculty of Medicine, Selcuk University, Konya 42130, Turkey.
  • Department of Radiology, Faculty of Medicine, Selcuk University, Konya, 42130, Turkey.

ORCID-Profile: Osman Vefa Gul

Zitieren

APA

Gul, O. V., Koplay, M., & Ozturk, M. (2026). Gantry tilt as a dose reduction strategy for radiosensitive organs in pediatric brain CT: a prospective TLD study. Radiation Protection Dosimetry. https://doi.org/10.1093/rpd/ncaf144

Vancouver

Gul OV, Koplay M, Ozturk M. Gantry tilt as a dose reduction strategy for radiosensitive organs in pediatric brain CT: a prospective TLD study. Radiation Protection Dosimetry. 2026. doi:10.1093/rpd/ncaf144

BibTeX
@article{Gul2026,
  author = {Gul, Osman Vefa and Koplay, Mustafa and Ozturk, Mehmet},
  title = {Gantry tilt as a dose reduction strategy for radiosensitive organs in pediatric brain CT: a prospective TLD study},
  journal = {Radiation Protection Dosimetry},
  year = {2026},
  doi = {10.1093/rpd/ncaf144}
}
Kostenlos starten →