Fachartikel in der Zeitschrift Radiation Protection Dosimetry, 2024. Verfasst von Idris Garba und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medical Imaging and Therapeutic Sciences, Faculty of Health and Wellness Sciences, Cape Peninsula University of Technology, Cape Town 8…. Hauptthemen laut MEDLINE: Tomography, X-Ray Computed, Radiation Dosage, Brain, Tertiary Care Centers. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 36 Literaturangaben.
Abstract (Originalsprache)
A manual radiation dose management system was developed to track the radiation dose and scan parameters of patients for brain computed tomography (CT). Radiation dose in volume computed tomography dose index (CTDIvol) and dose length product (DLP) were monitored to identify procedures that may require optimisation using notification values. The data were analysed and compared with national and international diagnostic reference levels (DRLs). A total of 596 brain CTs were monitored and grouped as <1: 36, 1–<5: 38, 5–<10: 25, 10–<15: 31 and adult: 466. The CTDIvol notification value identified the following number of examinations having high CTDIvol in <1 y: 1, 1–<5: 1, 5–<10: 0, 10–<15: 0 and adult (>15): 11. Furthermore, the DLP notification values identified the following examinations with high DLP in <1 y: 1, 1–<5:1, 5–<10:1, 10–<15: 1 and adults (>15): 18. The established local paediatric DLP DRLs were 2–3 times higher than the international paediatric DLP DRLs. This calls for a total protocol review and optimisation considering the local CT practices for paediatric imaging.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Medical Imaging and Therapeutic Sciences, Faculty of Health and Wellness Sciences, Cape Peninsula University of Technology, Cape Town 8000, South Africa.
- Department of Radiology, Faculty of Clinical Sciences, College of Health Sciences, Bayero University Kano, Kano 700001, Nigeria.
ORCID-Profile: Idris Garba
Zitieren
APA
Garba, I., Penelope, E. H., Davidson, F., & Ismail, A. (2024). Prospective dose monitoring using a manual dose management system: experience in brain computed tomography from a tertiary hospital in Nigeria. Radiation Protection Dosimetry. https://doi.org/10.1093/rpd/ncae094
Vancouver
Garba I, Penelope EH, Davidson F, Ismail A. Prospective dose monitoring using a manual dose management system: experience in brain computed tomography from a tertiary hospital in Nigeria. Radiation Protection Dosimetry. 2024. doi:10.1093/rpd/ncae094
BibTeX
@article{Garba2024,
author = {Garba, Idris and Penelope, Engel-Hills and Davidson, Florence and Ismail, Anas},
title = {Prospective dose monitoring using a manual dose management system: experience in brain computed tomography from a tertiary hospital in Nigeria},
journal = {Radiation Protection Dosimetry},
year = {2024},
doi = {10.1093/rpd/ncae094}
}
EUVIMED