EUVIMEDEUVIMED entdecken
Crossref

Model-based evaluation of point-source approximation error for extended radionuclide sources in nuclear medicine

Rhodri Smith iD, Bill Thomson, Hannah Nelstrop, Anthony Murray iD

Journal of Radiological Protection · 2026

DOI: 10.1088/1361-6498/ae8d2e ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Radiological Protection, 2026. Verfasst von Rhodri Smith und 3 weiteren Autor:innen. Beteiligte Einrichtung: Radiology and Diagnostic Imaging Department, Faculty of Medicine and Dentistry, University of Alberta, Edmonton, Alberta, Canada. Hauptthemen laut MEDLINE: Nuclear Medicine, Radioisotopes. Die Arbeit nennt 18 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Accurate estimation of external radiation exposure is essential in nuclear medicine (NM) for occupational safety and regulatory compliance. Point-source models are widely used because they are simple and require limited input data; however, their accuracy can degrade when radioactive material is distributed over extended line, surface, or volume geometries. This study evaluates point-source approximation error across a range of extended-source models, beginning with non-attenuating line and disc geometries and extending to attenuating finite-thickness slab and laterally viewed cylindrical volume sources. Absolute dose-rate examples were calculated using a Tc-99 m gamma constant, while relative error and correction-factor results were expressed using geometry- and attenuation-dependent parameters. For non-attenuating line and disc sources, point-source approximations can overestimate exposure by up to approximately 100% when source dimensions exceed the exposure distance. A practical threshold was identified: when the source dimension-to-distance ratio is less than one, point-source errors remain below 5%; above a ratio of 1, line or disc models should be considered or the point-source estimate corrected using the factors provided. For attenuating finite-thickness slab sources, an analytical correction factor was derived that separates into a lateral-extent term governed by the source diameter-to-distance ratio D / d , and an attenuation-thickness term governed by μ t . Together, these two dimensionless parameters allow point-source error to be mapped across combinations of source size, distance, attenuation coefficient and slab thickness. For laterally viewed cylindrical sources, kernel-based volume integration showed that point-source error depended jointly on L / d , D / d and μ d , where d is the surface-to-point distance. The 20% error region narrowed markedly as L / d ≈ 2 , indicating that patient-scale attenuating cylinders cannot be assessed from distance alone. Representative Tc-99 m examples showed modest error for a 5 ml syringe-scale cylinder at 1 m, but substantial overestimation for a patient-torso-scale cylinder. Comparison with published measured patient dose-rate studies showed that the patient-torso cylindrical model produced values of a similar order of magnitude to measured 1 m patient dose rates, whereas point-source estimates were generally higher. This paper provides practical correction factors, error-threshold maps and model-selection guidance to support more appropriate selection of source models in NM exposure assessments.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Nuclear MedicineRadioisotopesRadiation DosageComputer SimulationRadiation Protection

Stichwörter der Autor:innen

dose-rate modellingextended sourcesnuclear medicinepoint-kernel modellingpoint-source approximation

Substanzen

Radioisotopes

Autor:innen und Institutionen

  • Radiology and Diagnostic Imaging Department, Faculty of Medicine and Dentistry, University of Alberta, Edmonton, Alberta, Canada.
  • Department of Physics and Nuclear Medicine, Midland Metropolitan University Hospital, Sandwell and W Birmingham Hospitals NHS Trust, Birmingham, United Kingdom.
  • Department of Medical Physics and Clinical Engineering, Leeds Teaching Hospitals Trust, Leeds, United Kingdom.

ORCID-Profile: Rhodri Smith, Anthony Murray

Zitieren

APA

Smith, R., Thomson, B., Nelstrop, H., & Murray, A. (2026). Model-based evaluation of point-source approximation error for extended radionuclide sources in nuclear medicine. Journal of Radiological Protection. https://doi.org/10.1088/1361-6498/ae8d2e

Vancouver

Smith R, Thomson B, Nelstrop H, Murray A. Model-based evaluation of point-source approximation error for extended radionuclide sources in nuclear medicine. Journal of Radiological Protection. 2026. doi:10.1088/1361-6498/ae8d2e

BibTeX
@article{Smith2026,
  author = {Smith, Rhodri and Thomson, Bill and Nelstrop, Hannah and Murray, Anthony},
  title = {Model-based evaluation of point-source approximation error for extended radionuclide sources in nuclear medicine},
  journal = {Journal of Radiological Protection},
  year = {2026},
  doi = {10.1088/1361-6498/ae8d2e}
}
Kostenlos starten →