Model-based evaluation of point-source approximation error for extended radionuclide sources in nuclear medicine
Journal of Radiological Protection · 2026
DOI: 10.1088/1361-6498/ae8d2e ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Radiological Protection, 2026. Verfasst von Rhodri Smith und 3 weiteren Autor:innen. Beteiligte Einrichtung: Radiology and Diagnostic Imaging Department, Faculty of Medicine and Dentistry, University of Alberta, Edmonton, Alberta, Canada. Hauptthemen laut MEDLINE: Nuclear Medicine, Radioisotopes. Die Arbeit nennt 18 Literaturangaben.
Abstract (Originalsprache)
Accurate estimation of external radiation exposure is essential in nuclear medicine (NM) for occupational safety and regulatory compliance. Point-source models are widely used because they are simple and require limited input data; however, their accuracy can degrade when radioactive material is distributed over extended line, surface, or volume geometries. This study evaluates point-source approximation error across a range of extended-source models, beginning with non-attenuating line and disc geometries and extending to attenuating finite-thickness slab and laterally viewed cylindrical volume sources. Absolute dose-rate examples were calculated using a Tc-99 m gamma constant, while relative error and correction-factor results were expressed using geometry- and attenuation-dependent parameters. For non-attenuating line and disc sources, point-source approximations can overestimate exposure by up to approximately 100% when source dimensions exceed the exposure distance. A practical threshold was identified: when the source dimension-to-distance ratio is less than one, point-source errors remain below 5%; above a ratio of 1, line or disc models should be considered or the point-source estimate corrected using the factors provided. For attenuating finite-thickness slab sources, an analytical correction factor was derived that separates into a lateral-extent term governed by the source diameter-to-distance ratio D / d , and an attenuation-thickness term governed by μ t . Together, these two dimensionless parameters allow point-source error to be mapped across combinations of source size, distance, attenuation coefficient and slab thickness. For laterally viewed cylindrical sources, kernel-based volume integration showed that point-source error depended jointly on L / d , D / d and μ d , where d is the surface-to-point distance. The 20% error region narrowed markedly as L / d ≈ 2 , indicating that patient-scale attenuating cylinders cannot be assessed from distance alone. Representative Tc-99 m examples showed modest error for a 5 ml syringe-scale cylinder at 1 m, but substantial overestimation for a patient-torso-scale cylinder. Comparison with published measured patient dose-rate studies showed that the patient-torso cylindrical model produced values of a similar order of magnitude to measured 1 m patient dose rates, whereas point-source estimates were generally higher. This paper provides practical correction factors, error-threshold maps and model-selection guidance to support more appropriate selection of source models in NM exposure assessments.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Radiology and Diagnostic Imaging Department, Faculty of Medicine and Dentistry, University of Alberta, Edmonton, Alberta, Canada.
- Department of Physics and Nuclear Medicine, Midland Metropolitan University Hospital, Sandwell and W Birmingham Hospitals NHS Trust, Birmingham, United Kingdom.
- Department of Medical Physics and Clinical Engineering, Leeds Teaching Hospitals Trust, Leeds, United Kingdom.
ORCID-Profile: Rhodri Smith, Anthony Murray
Zitieren
APA
Smith, R., Thomson, B., Nelstrop, H., & Murray, A. (2026). Model-based evaluation of point-source approximation error for extended radionuclide sources in nuclear medicine. Journal of Radiological Protection. https://doi.org/10.1088/1361-6498/ae8d2e
Vancouver
Smith R, Thomson B, Nelstrop H, Murray A. Model-based evaluation of point-source approximation error for extended radionuclide sources in nuclear medicine. Journal of Radiological Protection. 2026. doi:10.1088/1361-6498/ae8d2e
BibTeX
@article{Smith2026,
author = {Smith, Rhodri and Thomson, Bill and Nelstrop, Hannah and Murray, Anthony},
title = {Model-based evaluation of point-source approximation error for extended radionuclide sources in nuclear medicine},
journal = {Journal of Radiological Protection},
year = {2026},
doi = {10.1088/1361-6498/ae8d2e}
}
EUVIMED