EUVIMEDEUVIMED entdecken
Crossref

Establishing national diagnostic reference levels for adult nuclear medicine single-photon emission computed tomography imaging in Bahrain

Mohamed Khaled Bucheer iD, Wadha Alyami iD

Radiation Protection Dosimetry · 02.11.2026 · 202 (18) · 1486-1492

DOI: 10.1093/rpd/ncag086 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Radiation Protection Dosimetry, online erschienen am 06.08.2026. Verfasst von Mohamed Khaled Bucheer und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiological Sciences, College of Applied Medical Sciences, King Saud University, P.O. Box 10219, Riyadh 11433, Saudi Arabia. Hauptthemen laut MEDLINE: Tomography, Emission-Computed, Single-Photon, Nuclear Medicine, Radiation Protection, Radiopharmaceuticals. Die Arbeit nennt 22 Literaturangaben. Gefördert von: Ongoing Research Funding Program, King Saud University, Riyadh, Saudi Arabia.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study established diagnostic reference levels (DRLs) for common adult single-photon emission computed tomography (SPECT) procedures in Bahrain to support dose optimization and alignment with international radiation protection standards. Data were retrospectively collected from two major nuclear medicine centers, representing most national SPECT services. Administered radiopharmaceutical activities (MBq) for adult patients (70 kg ± 20%) undergoing routine examinations were analyzed. DRLs were calculated as the 75th percentile of administered activity following International Commission on Radiological Protection (ICRP) Publication 135. A total of 1098 studies were included. Variations between centers reflected differences in administration practices. Overall, Bahrain’s proposed DRLs were lower than regional values reported in Kuwait and Saudi Arabia and were comparable to European benchmarks. The findings provide a national reference framework for optimization of nuclear medicine practice and support ongoing monitoring to maintain compliance with international radiation safety recommendations from the ICRP and International Atomic Energy Agency.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Tomography, Emission-Computed, Single-PhotonNuclear MedicineRadiation ProtectionRadiopharmaceuticalsHumansBahrainDiagnostic Reference LevelsRadiation DosageAdultRetrospective StudiesReference Values

Substanzen

Radiopharmaceuticals

Autor:innen und Institutionen

  • Department of Radiological Sciences, College of Applied Medical Sciences, King Saud University, P.O. Box 10219, Riyadh 11433, Saudi Arabia.
  • Nuclear Medicine Department, King Hamad University Hospital, Royal Medical Services, Building 2345, Road 2835, Block 228, P.O. Box 24343, Busaiteen, Kingdom of Bahrain.

ORCID-Profile: Mohamed Khaled Bucheer, Wadha Alyami

Förderung

  • Ongoing Research Funding Program
  • King Saud University, Riyadh, Saudi Arabia

Zitieren

APA

Bucheer, M. K., & Alyami, W. (2026). Establishing national diagnostic reference levels for adult nuclear medicine single-photon emission computed tomography imaging in Bahrain. Radiation Protection Dosimetry, 202(18), 1486-1492. https://doi.org/10.1093/rpd/ncag086

Vancouver

Bucheer MK, Alyami W. Establishing national diagnostic reference levels for adult nuclear medicine single-photon emission computed tomography imaging in Bahrain. Radiation Protection Dosimetry. 2026;202(18):1486-1492. doi:10.1093/rpd/ncag086

BibTeX
@article{Bucheer2026,
  author = {Bucheer, Mohamed Khaled and Alyami, Wadha},
  title = {Establishing national diagnostic reference levels for adult nuclear medicine single-photon emission computed tomography imaging in Bahrain},
  journal = {Radiation Protection Dosimetry},
  year = {2026},
  volume = {202},
  number = {18},
  pages = {1486--1492},
  doi = {10.1093/rpd/ncag086}
}
Kostenlos starten →