Establishing national diagnostic reference levels for adult nuclear medicine single-photon emission computed tomography imaging in Bahrain
Radiation Protection Dosimetry · 02.11.2026 · 202 (18) · 1486-1492
DOI: 10.1093/rpd/ncag086 ↗Kurz gefasst
Fachartikel in der Zeitschrift Radiation Protection Dosimetry, online erschienen am 06.08.2026. Verfasst von Mohamed Khaled Bucheer und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiological Sciences, College of Applied Medical Sciences, King Saud University, P.O. Box 10219, Riyadh 11433, Saudi Arabia. Hauptthemen laut MEDLINE: Tomography, Emission-Computed, Single-Photon, Nuclear Medicine, Radiation Protection, Radiopharmaceuticals. Die Arbeit nennt 22 Literaturangaben. Gefördert von: Ongoing Research Funding Program, King Saud University, Riyadh, Saudi Arabia.
Abstract (Originalsprache)
This study established diagnostic reference levels (DRLs) for common adult single-photon emission computed tomography (SPECT) procedures in Bahrain to support dose optimization and alignment with international radiation protection standards. Data were retrospectively collected from two major nuclear medicine centers, representing most national SPECT services. Administered radiopharmaceutical activities (MBq) for adult patients (70 kg ± 20%) undergoing routine examinations were analyzed. DRLs were calculated as the 75th percentile of administered activity following International Commission on Radiological Protection (ICRP) Publication 135. A total of 1098 studies were included. Variations between centers reflected differences in administration practices. Overall, Bahrain’s proposed DRLs were lower than regional values reported in Kuwait and Saudi Arabia and were comparable to European benchmarks. The findings provide a national reference framework for optimization of nuclear medicine practice and support ongoing monitoring to maintain compliance with international radiation safety recommendations from the ICRP and International Atomic Energy Agency.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Department of Radiological Sciences, College of Applied Medical Sciences, King Saud University, P.O. Box 10219, Riyadh 11433, Saudi Arabia.
- Nuclear Medicine Department, King Hamad University Hospital, Royal Medical Services, Building 2345, Road 2835, Block 228, P.O. Box 24343, Busaiteen, Kingdom of Bahrain.
ORCID-Profile: Mohamed Khaled Bucheer, Wadha Alyami
Förderung
- Ongoing Research Funding Program
- King Saud University, Riyadh, Saudi Arabia
Zitieren
APA
Bucheer, M. K., & Alyami, W. (2026). Establishing national diagnostic reference levels for adult nuclear medicine single-photon emission computed tomography imaging in Bahrain. Radiation Protection Dosimetry, 202(18), 1486-1492. https://doi.org/10.1093/rpd/ncag086
Vancouver
Bucheer MK, Alyami W. Establishing national diagnostic reference levels for adult nuclear medicine single-photon emission computed tomography imaging in Bahrain. Radiation Protection Dosimetry. 2026;202(18):1486-1492. doi:10.1093/rpd/ncag086
BibTeX
@article{Bucheer2026,
author = {Bucheer, Mohamed Khaled and Alyami, Wadha},
title = {Establishing national diagnostic reference levels for adult nuclear medicine single-photon emission computed tomography imaging in Bahrain},
journal = {Radiation Protection Dosimetry},
year = {2026},
volume = {202},
number = {18},
pages = {1486--1492},
doi = {10.1093/rpd/ncag086}
}
EUVIMED