EUVIMEDEUVIMED entdecken
Crossref

A proposal for the performance evaluation of 0.5 mm lead aprons used in nuclear medicine

Sangho Lee, Donggun Jang iD

Radiation Protection Dosimetry · 2024

DOI: 10.1093/rpd/ncad305 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Radiation Protection Dosimetry, 2024. Verfasst von Sangho Lee und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiological Technology, Daegu Health College, 15, Yeongsong-ro, Buk-gu, Daegu, 41453, Republic of Korea. Hauptthemen laut MEDLINE: Nuclear Medicine, Radiation Protection. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 14 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The lead apron plays a crucial role in radiation protection and is extensively used in medical institutions. Periodic performance evaluations, involving visual inspections and transmission imaging, are conducted annually. This research aims to propose a performance evaluation method for 0.5 mm lead aprons used in nuclear medicine departments. The experiments were conducted using transmission imaging and source-based evaluation methods, involving two lead aprons with <1 year of use and two other aprons used for over 10 years. The experimental results indicate that using 50 kVp for transmission imaging is appropriate to detect cracks in the lead aprons. Additionally, in the case of lead aprons used for >10 years, the measured attenuation rate was found to be ~3–5% lower, depending on the measurement method. Consequently, a performance evaluation, including crack detection and actual attenuation rate measurements, should be carried out for lead aprons used long-term to ensure efficacy of radiation protection.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Nuclear MedicineRadiation ProtectionRadiation DosageRadionuclide ImagingProtective Clothing

Autor:innen und Institutionen

  • Department of Radiological Technology, Daegu Health College, 15, Yeongsong-ro, Buk-gu, Daegu, 41453, Republic of Korea.
  • KEPCO International Nuclear Graduate School, 658-91, Haemaji-ro, Seosaeng-myeon, Ulju-gun, Ulsan, 45014, Republic of Korea.

ORCID-Profile: Donggun Jang

Zitieren

APA

Lee, S., & Jang, D. (2024). A proposal for the performance evaluation of 0.5 mm lead aprons used in nuclear medicine. Radiation Protection Dosimetry. https://doi.org/10.1093/rpd/ncad305

Vancouver

Lee S, Jang D. A proposal for the performance evaluation of 0.5 mm lead aprons used in nuclear medicine. Radiation Protection Dosimetry. 2024. doi:10.1093/rpd/ncad305

BibTeX
@article{Lee2024,
  author = {Lee, Sangho and Jang, Donggun},
  title = {A proposal for the performance evaluation of 0.5 mm lead aprons used in nuclear medicine},
  journal = {Radiation Protection Dosimetry},
  year = {2024},
  doi = {10.1093/rpd/ncad305}
}
Kostenlos starten →