Dosimetric comparability validation of small animal photon and neutron irradiations
Journal of Radiological Protection · 2026
DOI: 10.1088/1361-6498/ae33cd ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Journal of Radiological Protection, 2026. Verfasst von Sebastian Tattenberg und 7 weiteren Autor:innen. Beteiligte Einrichtung: Laurentian University, Sudbury P3E 2C6, Ontario, Canada. Hauptthemen laut MEDLINE: Photons, Neutrons, Radiometry. Die Arbeit nennt 22 Literaturangaben. Gefördert von: Mitacs, National Research Council of Canada.
Abstract (Originalsprache)
Crew members on missions beyond low-earth orbit receive considerable radiation doses, but the effects and relative biological effectiveness of many relevant types of irradiation, including neutrons with energies of hundreds of MeV, largely remain under-investigated. Such small animal irradiations can only be compared to respective photon irradiations if comparable doses can simultaneously be delivered to a variety of organs during both irradiations, despite the different underlying dose deposition patterns. To evaluate the dosimetric comparability of upcoming small animal neutron and photon irradiations, experimental depth-dose measurements were performed at the TRIUMF neutron facility and the British Columbia Cancer Research Centre, using a neutron beam with energies of up to 450 MeV and a Cs-137 irradiator. The MOBY digital mouse phantom was used to perform Monte Carlo simulations of neutron and photon animal irradiations. Evaluated metrics included the ratio between the dose delivered to a variety of different organs (including lungs, brain, and heart) during neutron and photon irradiation. A sensitivity analysis including a variety of animal parameters (tissue elemental compositions and mass densities, animal size, and animal orientation) was performed, and the statistical significance ( p < 0.05) of the dosimetric impact of uncertainties in simulation parameters was analyzed. During nominal simulations, differences in organ doses during neutron and photon irradiation were
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Laurentian University, Sudbury P3E 2C6, Ontario, Canada.
- TRIUMF, Vancouver V6T 2A3, British Columbia, Canada.
- BC Cancer Research Institute, Vancouver, British Columbia V5Z 0A6, Canada.
- Duke University, Durham, NC 27710, United States of America.
- Canadian Nuclear Laboratories, Chalk River K0J 1J0, Ontario, Canada.
ORCID-Profile: Sebastian Tattenberg, Alex Hands, Camille Bélanger-Champagne, Cornelia Hoehr
Förderung
- Mitacs
- National Research Council of Canada
Zitieren
APA
Tattenberg, S., Hands, A., Bélanger-Champagne, C., Johnstone, C., Segars, W. P., Minchinton, A., Vazquez, M., & Hoehr, C. (2026). Dosimetric comparability validation of small animal photon and neutron irradiations. Journal of Radiological Protection. https://doi.org/10.1088/1361-6498/ae33cd
Vancouver
Tattenberg S, Hands A, Bélanger-Champagne C, Johnstone C, Segars WP, Minchinton A, et al. Dosimetric comparability validation of small animal photon and neutron irradiations. Journal of Radiological Protection. 2026. doi:10.1088/1361-6498/ae33cd
BibTeX
@article{Tattenberg2026,
author = {Tattenberg, Sebastian and Hands, Alex and Bélanger-Champagne, Camille and Johnstone, Chris and Segars, William Paul and Minchinton, Andrew and Vazquez, Marcelo and Hoehr, Cornelia},
title = {Dosimetric comparability validation of small animal photon and neutron irradiations},
journal = {Journal of Radiological Protection},
year = {2026},
doi = {10.1088/1361-6498/ae33cd}
}
EUVIMED