Comparison of casted and extruded PMMA plate used in microfluidics
Journal of Micromechanics and Microengineering · 01.08.2026 · 36 (8) · 085007
DOI: 10.1088/1361-6439/ae8e85 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Micromechanics and Microengineering, online erschienen am 10.08.2026. Verfasst von Yiqiang Fan und 5 weiteren Autor:innen. Die Arbeit nennt 32 Literaturangaben. Gefördert von: Nanjing University of Science and Technology, Self-fund Project of Langfang Science and Technology, Natural Science Foundation of Hebei Province.
Abstract (Originalsprache)
polymethyl methacrylate (PMMA) has been widely used in microfluidics, with the advantages of low cost, easy to process, and optical clarity. PMMA (usually in the form of a plate) can be processed with laser ablation, mechanical milling, hot embossing, and other approaches to form the microstructures and then bonded with another layer of PMMA plate to seal the channel. In the past decade, hundreds of studies have been reported on PMMA-based microfluidics. However, one key piece of information is usually neglected, that is, the PMMA plates used in these studies were fabricated either by casting or extrusion, but this difference is usually overlooked. In this study, we compared the cast and extruded PMMA plates used in microfluidics from various aspects, including optical transparency, surface finishing after laser ablation, and contact angle recovery after surface treatment. After oxygen plasma treatment, the contact angle after recovery is 21° for extruded PMMA and 44° for cast PMMA. PMMA shrinks isotropically in both directions by around 1.8%, while the extruded PMMA plate shrinks anisotropically, with 0.4% shrinkage in one direction and 1.5% in another direction. The surface finishing after laser ablation on cast and extruded PMMA also shows significant differences. We believe this study could be helpful in choosing cast or extruded PMMA plates for PMMA-based microfluidics.
Förderung
- Nanjing University of Science and Technology
- Self-fund Project of Langfang Science and Technology
- Natural Science Foundation of Hebei Province
Zitieren
APA
Fan, Y., Ding, S., Zhang, S., Han, W., Wang, Y., & Zhang, J. (2026). Comparison of casted and extruded PMMA plate used in microfluidics. Journal of Micromechanics and Microengineering, 36(8), 085007. https://doi.org/10.1088/1361-6439/ae8e85
Vancouver
Fan Y, Ding S, Zhang S, Han W, Wang Y, Zhang J. Comparison of casted and extruded PMMA plate used in microfluidics. Journal of Micromechanics and Microengineering. 2026;36(8):085007. doi:10.1088/1361-6439/ae8e85
BibTeX
@article{Fan2026,
author = {Fan, Yiqiang and Ding, Siyuan and Zhang, Shicheng and Han, Wenxu and Wang, Yuxuan and Zhang, Jing},
title = {Comparison of casted and extruded PMMA plate used in microfluidics},
journal = {Journal of Micromechanics and Microengineering},
year = {2026},
volume = {36},
number = {8},
pages = {085007},
doi = {10.1088/1361-6439/ae8e85}
}
EUVIMED