Effects of Evaluation Design on Model Comparison and Selection in Droplet Microfluidics
Micromachines · 19.11.2026 · 17 (11) · 1344
DOI: 10.3390/mi17111344 ↗Kurz gefasst
Fachartikel in der Zeitschrift Micromachines, online erschienen am 19.11.2026. Verfasst von Yunfeng Xing und 2 weiteren Autor:innen. Die Arbeit nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China, Base for Innovative Methods Promotion Application and Demonstration of Anhui Province,, Research and Application of Key Technologies for Monitoring the Status of Rotating Parts in Mechanical Equipment.
Abstract (Originalsprache)
Machine learning can predict microfluidic droplet size, but the best-performing model for familiar channel geometries may not suit new geometries. Using published flow-focusing droplet data, we compared model recommendations from different evaluation schemes and their predictive outcomes on unseen geometries. With matched training and test record counts in the main dataset, holding out all records of selected geometries increased the gradient-boosted tree model’s mean absolute diameter error from 8.29 to 12.22 µm, a 47.4% increase over random splitting, and reversed its ranking relative to the random forest. We then tested models recommended by the two validation schemes on the same geometries unseen during training. Those selected by geometry-grouped validation had an 8.2% lower mean absolute diameter error, averaged with equal weight per geometry, than those selected by random validation. Fixed random forest had the lowest error. In both candidate sets, operating conditions recommended by models selected through grouped validation had a smaller mean absolute deviation of measured diameter from the target than those recommended using random validation. At ±10% tolerance, the attainment ranking of the two rules depended on the candidate set. Model recommendations for new geometries should therefore be assessed on the same unseen geometries, while target-size recommendations require direct evaluation of the proportion meeting the specified tolerance.
Förderung
- National Natural Science Foundation of China
- Base for Innovative Methods Promotion Application and Demonstration of Anhui Province,
- Research and Application of Key Technologies for Monitoring the Status of Rotating Parts in Mechanical Equipment
Zitieren
APA
Xing, Y., Liu, Y., & Tang, Q. (2026). Effects of Evaluation Design on Model Comparison and Selection in Droplet Microfluidics. Micromachines, 17(11), 1344. https://doi.org/10.3390/mi17111344
Vancouver
Xing Y, Liu Y, Tang Q. Effects of Evaluation Design on Model Comparison and Selection in Droplet Microfluidics. Micromachines. 2026;17(11):1344. doi:10.3390/mi17111344
BibTeX
@article{Xing2026,
author = {Xing, Yunfeng and Liu, Yuwen and Tang, Qiang},
title = {Effects of Evaluation Design on Model Comparison and Selection in Droplet Microfluidics},
journal = {Micromachines},
year = {2026},
volume = {17},
number = {11},
pages = {1344},
doi = {10.3390/mi17111344}
}
EUVIMED