Single cell micro-absorption spectroscopy system with temperature control: System design and spectral analysis
Review of Scientific Instruments · 2024
DOI: 10.1063/5.0240029 ↗At a glance
Journal article in Review of Scientific Instruments, 2024. Written by Yufei Liu and 10 co-authors. Institution: School of Biomedical Engineering, Anhui Medical University, Hefei 230032, China. Major MEDLINE topics: Single-Cell Analysis, Temperature, Spectrum Analysis, Equipment Design. Cited 1 times so far (Crossref); 26 references. Funded by: University Natural Science Research Project of Anhui Province, Scientific Research Foundation of Education Department of Anhui Province of China.
Abstract (original language)
Micro-absorption spectroscopy is a useful tool for studying the biological characteristics of single cells. However, the weak spectral signal, due to low absorption caused by the tiny optical path length of the cell, makes the spectral data noisy and difficult to analyze. This paper describes a device for single-cell microspectroscopy measurement that integrates an optical fiber spectrometer and an image CCD within a microscopic system, allowing for the simultaneous acquisition of morphology information and the absorption spectrum of a single cell. The device utilizes an illumination source driven by modulated current sources instead of constant current sources and the corresponding spectral signal extraction method to reduce noise levels. It also features a transparent temperature-controlled sample chamber for regulating the sample’s temperature, as the absorption of cells may change with temperature. Due to the unwanted baseline drift in the spectral signals, a method of analyzing the similarity degree between the measured spectrum and the standard spectrum is proposed to study the characteristic variation of cells. To verify the feasibility of this method, the device was used for the microscopic spectral measurement and analysis of single red blood cells. The results showed that the variation patterns of spectral parameters correspond to the cell's responses to changes in temperature and storage duration.
Subjects
MeSH terms (MEDLINE)
Authors and institutions
- School of Biomedical Engineering, Anhui Medical University, Hefei 230032, China.
- Department of Medical Engineering, The First Affiliated Hospital of Anhui Medical University, Hefei 230032, China.
- The First People's Hospital of Chuzhou, The Affiliated Chuzhou Hospital of Anhui Medical University, Chuzhou, Anhui 239001, China.
- Shanghai Key Laboratory of Multidimensional Information Processing, East China Normal University, Shanghai 200241, China.
ORCID profiles: Bo Li, Zhensheng Zhong, Jinhua Zhou, Shengzhao Zhang, Zhen Liang, Mei Zhou
Funding
- University Natural Science Research Project of Anhui Province
- Scientific Research Foundation of Education Department of Anhui Province of China
Cite
APA
Liu, Y., Li, B., Sun, Y., Li, C., Lu, F., Zhong, Z., Zhou, J., Xie, Y., Zhang, S., Liang, Z., & Zhou, M. (2024). Single cell micro-absorption spectroscopy system with temperature control: System design and spectral analysis. Review of Scientific Instruments. https://doi.org/10.1063/5.0240029
Vancouver
Liu Y, Li B, Sun Y, Li C, Lu F, Zhong Z, et al. Single cell micro-absorption spectroscopy system with temperature control: System design and spectral analysis. Review of Scientific Instruments. 2024. doi:10.1063/5.0240029
BibTeX
@article{Liu2024,
author = {Liu, Yufei and Li, Bo and Sun, Yue and Li, Changxu and Lu, Fengya and Zhong, Zhensheng and Zhou, Jinhua and Xie, Yingying and Zhang, Shengzhao and Liang, Zhen and Zhou, Mei},
title = {Single cell micro-absorption spectroscopy system with temperature control: System design and spectral analysis},
journal = {Review of Scientific Instruments},
year = {2024},
doi = {10.1063/5.0240029}
}
EUVIMED