EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Influence of Clinically Relevant Seating Loads on Shear-Thinning Behavior and Film Thickness of Light-Cure Veneer Cements

Randa Sabry Ibrahim iD

European Journal of Dentistry · 11.09.2026

DOI: 10.1055/s-0046-1827464 ↗

Kurz gefasst

Fachartikel in der Zeitschrift European Journal of Dentistry, erschienen am 11.09.2026. Verfasst von Randa Sabry Ibrahim. Beteiligte Einrichtung: Department of Restorative and Prosthetic Dental Sciences, College of Dentistry, King Saud bin Abdulaziz University for Health Sciences, Riyadh, Saudi…. Die Arbeit nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This article aims to evaluate the shear rate-dependent rheological behavior of light-cure resin cements used for lithium disilicate veneers and assess its relationship with cement film thickness under standardized and clinically relevant seating loads. Five light-cure resin cements (RXV, CVE, ACV, NXL, and VLE) were tested using rotational rheometry under a standardized baseline gap. Apparent viscosity (η) was determined at 10 s−1 and 100 s−1. Cement film thickness was measured following ISO 4049 under 150 N and under reduced loads of 50 and 30 N. All measurements were performed in triplicate (n = 3 per cement for rheology; n = 3 per cement per seating load for film thickness). Data were analyzed using one-way and two-way analysis of variance (ANOVA), followed by Tukey post hoc tests where appropriate. Linear regression and Pearson's correlation analyses were used to examine load-film thickness trends and viscosity-film thickness associations. The significance level was set at α = 0.05. Viscosity differed significantly among materials at both shear rates (p < 0.001). At 10 s−1, viscosity ranged from 210 ± 2 Pa·s (VLE) to 1820 ± 20 Pa·s (NXL), while at 100 s−1 it ranged from 164 ± 2 Pa·s (RXV) to 440 ± 2 Pa·s (VLE). Four cements showed pronounced shear-thinning behavior (−82.6% to −86.3%), whereas VLE showed an inverse response (-109.5%). Film thickness differed significantly across all seating loads (150 N: p = 0.004; 50 and 30 N: p < 0.001). At 30 N, values ranged from 48.3 ± 3.5 µm (RXV) to 74.7 ± 2.5 µm (NXL). Weak positive associations were observed between viscosity and film thickness under reduced seating conditions (r = 0.25 at 30 N; r = 0.24 at 50 N). Seating load was the main determinant of cement film thickness, while shear rate-dependent viscosity showed a secondary, material-dependent contribution under reduced pressure. Favorable shear-thinning behavior may support improved seating adaptation and more consistent film thickness control during veneer placement.

Autor:innen und Institutionen

  • Department of Restorative and Prosthetic Dental Sciences, College of Dentistry, King Saud bin Abdulaziz University for Health Sciences, Riyadh, Saudi Arabia.
  • King Abdullah International Medical Research Center, Riyadh, Saudi Arabia.
  • Ministry of National Guard Health Affairs, Riyadh, Saudi Arabia.
  • Department of Dental Biomaterials, Faculty of Dentistry, Tanta University, Tanta, Egypt.

ORCID-Profile: Randa Sabry Ibrahim

Zitieren

APA

Ibrahim, R. S. (2026). Influence of Clinically Relevant Seating Loads on Shear-Thinning Behavior and Film Thickness of Light-Cure Veneer Cements. European Journal of Dentistry. https://doi.org/10.1055/s-0046-1827464

Vancouver

Ibrahim RS. Influence of Clinically Relevant Seating Loads on Shear-Thinning Behavior and Film Thickness of Light-Cure Veneer Cements. European Journal of Dentistry. 2026. doi:10.1055/s-0046-1827464

BibTeX
@article{Ibrahim2026,
  author = {Ibrahim, Randa Sabry},
  title = {Influence of Clinically Relevant Seating Loads on Shear-Thinning Behavior and Film Thickness of Light-Cure Veneer Cements},
  journal = {European Journal of Dentistry},
  year = {2026},
  doi = {10.1055/s-0046-1827464}
}
Kostenlos starten →