EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Effect of Dental CAD-CAM Resin Composite Thickness on the Polymerization Behavior of Dual-Cure Resin Cements for Endocrown Restoration

Yuya Komagata, Takafumi Watanabe iD, Shinji Yoshii, Chihiro Masaki, Hiroshi Ikeda iD

Materials · 19.03.2026 · 19 (6) · 1217

DOI: 10.3390/ma19061217 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Materials, online erschienen am 19.03.2026. Verfasst von Yuya Komagata und 4 weiteren Autor:innen. Beteiligte Einrichtung: Division of Biomaterials, Kyushu Dental University, Kitakyushu 803-8580, Japan. Die Arbeit nennt 58 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Japan Society for the Promotion of Science, JSPS KAKENHI.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study investigated the effect of CAD-CAM resin composite thickness on the polymerization behavior of dual-cure resin cements used for endocrown restorations. Three commercially available dual-cure resin cements and one light-cure resin cement (for comparison) were polymerized by light irradiation through CAD-CAM resin composite plates of varying thicknesses (1.5, 3.5, 5.5, 7.5, and 9.5 mm). Transmitted light intensity was measured using an optical spectrometer. Polymerization behavior was evaluated immediately after irradiation and after 24 h of aging using Fourier transform infrared spectroscopy to determine the degree of conversion (DC) and Vickers hardness (VH) testing. Transmitted light intensity decreased logarithmically with increasing composite thickness, with less than 1% of incident light reaching the resin cement at thicknesses ≥ 5.5 mm. For the dual-cure resin cements, DC and VH values significantly decreased when the composite thickness exceeded 5.5 mm. Although DC and VH increased after 24 h due to self-curing, values beneath thicker composites remained lower than those beneath 1.5 mm thick composites. The light-cure resin cement failed to polymerize when the composite thickness exceeded 7.5 mm. These results indicate that CAD-CAM resin composite thickness critically influences resin cement polymerization, highlighting the importance of thickness control in endocrown restorations.

Schlagwörter

Stichwörter der Autor:innen

CAD-CAM materialdegree of conversiondual-cure resin cementendocrownhardnesslight-cure resin cement

Autor:innen und Institutionen

  • Division of Biomaterials, Kyushu Dental University, Kitakyushu 803-8580, Japan.
  • Division of Occlusion and Maxillofacial Reconstruction, Kyushu Dental University, Kitakyushu 803-8580, Japan.
  • Division of Promoting Learning Design Education, Kyushu Dental University, Kitakyushu 803-8580, Japan.
  • Division of Oral Reconstruction and Rehabilitation, Kyushu Dental University, Kitakyushu 803-8580, Japan.

ORCID-Profile: Takafumi Watanabe, Hiroshi Ikeda

Förderung

  • Japan Society for the Promotion of Science
  • JSPS KAKENHI

Zitieren

APA

Komagata, Y., Watanabe, T., Yoshii, S., Masaki, C., & Ikeda, H. (2026). Effect of Dental CAD-CAM Resin Composite Thickness on the Polymerization Behavior of Dual-Cure Resin Cements for Endocrown Restoration. Materials, 19(6), 1217. https://doi.org/10.3390/ma19061217

Vancouver

Komagata Y, Watanabe T, Yoshii S, Masaki C, Ikeda H. Effect of Dental CAD-CAM Resin Composite Thickness on the Polymerization Behavior of Dual-Cure Resin Cements for Endocrown Restoration. Materials. 2026;19(6):1217. doi:10.3390/ma19061217

BibTeX
@article{Komagata2026,
  author = {Komagata, Yuya and Watanabe, Takafumi and Yoshii, Shinji and Masaki, Chihiro and Ikeda, Hiroshi},
  title = {Effect of Dental CAD-CAM Resin Composite Thickness on the Polymerization Behavior of Dual-Cure Resin Cements for Endocrown Restoration},
  journal = {Materials},
  year = {2026},
  volume = {19},
  number = {6},
  pages = {1217},
  doi = {10.3390/ma19061217}
}
Kostenlos starten →