EUVIMEDEUVIMED entdecken
Crossref

Stress Evaluation of Indirect Composite Superstructure on Different Copings in CAD-on Technique for Restoration of Titanium Dental Implants—3D Finite Element Analysis

Sahithi Bandi, Kiran Kumar Pandurangan, Subhabrata Maiti, Delphine Priscilla Antony, Mario Alberto Alarcón-Sánchez, Artak Heboyan, Gustavo Eder González-Alvarez, Sarah Monserrat Lomelí-Martínez

European Journal of General Dentistry · 01.08.2026

DOI: 10.1055/s-0046-1825865 ↗

Kurz gefasst

Fachartikel in der Zeitschrift European Journal of General Dentistry, erschienen am 01.08.2026. Verfasst von Sahithi Bandi und 7 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Aim

The aim of the study is to evaluate and compare the stress distribution and total deformation of indirect composite veneered superstructures fabricated using different coping materials—zirconia, biocompatible high-performance polymer (BioHPP), and polyetherketoneketone (PEKK)—via the CAD-on technique using three-dimensional (3D) finite element analysis.

Methods

A 3D finite element model of a mandibular second premolar restored with a 4.1 × 12 mm titanium implant and internal hex abutment was digitally reconstructed. Four restorative configurations were analyzed: (G1) zirconia coping with hand-layered ceramic veneer, (G2) zirconia coping with HIPC veneer, (G3) BioHPP coping with HIPC veneer, and (G4) PEKK coping with HIPC veneer. Models were developed in ANSYS Workbench 2022 R2 and subjected to a static vertical load of 280 N applied over the occlusal surface. Von Mises stress and total deformation were measured at the coping, abutment, and implant interfaces. Data were analyzed using one-way ANOVA (Analysis of Variance) and Tukey's post-hoc test (α = 0.05).

Results

The highest stress occurred in G1 (29.62 ± 37.73 MPa) at the implant margin, while the lowest values were noted in G3 (13.05 ± 9.63 MPa at the coping; 14.13 ± 2.06 MPa at the abutment). Total deformation differed significantly among groups (p

Zitieren

APA

Bandi, S., Pandurangan, K. K., Maiti, S., Antony, D. P., Alarcón-Sánchez, M. A., Heboyan, A., González-Alvarez, G. E., & Lomelí-Martínez, S. M. (2026). Stress Evaluation of Indirect Composite Superstructure on Different Copings in CAD-on Technique for Restoration of Titanium Dental Implants—3D Finite Element Analysis. European Journal of General Dentistry. https://doi.org/10.1055/s-0046-1825865

Vancouver

Bandi S, Pandurangan KK, Maiti S, Antony DP, Alarcón-Sánchez MA, Heboyan A, et al. Stress Evaluation of Indirect Composite Superstructure on Different Copings in CAD-on Technique for Restoration of Titanium Dental Implants—3D Finite Element Analysis. European Journal of General Dentistry. 2026. doi:10.1055/s-0046-1825865

BibTeX
@article{Bandi2026,
  author = {Bandi, Sahithi and Pandurangan, Kiran Kumar and Maiti, Subhabrata and Antony, Delphine Priscilla and Alarcón-Sánchez, Mario Alberto and Heboyan, Artak and González-Alvarez, Gustavo Eder and Lomelí-Martínez, Sarah Monserrat},
  title = {Stress Evaluation of Indirect Composite Superstructure on Different Copings in CAD-on Technique for Restoration of Titanium Dental Implants—3D Finite Element Analysis},
  journal = {European Journal of General Dentistry},
  year = {2026},
  doi = {10.1055/s-0046-1825865}
}
Kostenlos starten →