Vergleichsstudie in der Zeitschrift Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, online erschienen am 19.07.2026. Verfasst von Melody Chase-Diaz und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Operative Dentistry, Endodontics and Dental Materials, Bauru School of Dentistry, University of São Paulo (USP), Bauru, Brazil. Hauptthemen laut MEDLINE: Titanium, Finite Element Analysis, Dental Implants, Zirconium. Die Arbeit nennt 45 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Yttria-stabilized tetragonal zirconia polycrystal (Y-TZP) implants have been proposed as an alternative to titanium (Ti) implants because of their aesthetic and mechanical properties. This in silico study compared the elastic strain distribution of Y-TZP and Ti dental implants under axial and oblique loads using a previously validated finite element model. Two finite element models, with identical geometry, boundary conditions, loading configuration, prosthetic crown, abutment, and screws, and differing only in implant body material, were constructed for biomechanical evaluation. Each model was subjected to a 300 N load applied axially and at 30°, and equivalent, maximum principal, and minimum principal elastic strains were evaluated in the peri-implant bone, implant body, and abutment screw. Under axial loading, peri-implant bone strain patterns were similar between Ti and Y-TZP, with peak equivalent elastic strain values of approximately 5 millistrain. Under oblique loading, the Y-TZP implant showed lower equivalent elastic strain in the implant body than Ti, with values of approximately 1.3 and 3.0 millistrain, respectively. The abutment screw also showed smaller regions of elevated strain in the Y-TZP model. Within the assumptions of this static linear elastic model, implant material stiffness influenced component-level elastic strain distribution, particularly under oblique loading. These numerical findings should not be interpreted as evidence of improved clinical performance, reduced bone resorption, or superior long-term stability. Further studies should include cyclic loading, fracture and fatigue analyses, interface stability, and patient-specific bone conditions.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

TitaniumFinite Element AnalysisDental ImplantsZirconiumYttriumBiomechanical PhenomenaMaterials TestingStress, Mechanical

Stichwörter der Autor:innen

dental biomechanicsdental implantselastic strainfinite element analysisimplant-supported prosthesistitaniumzirconia

Substanzen

TitaniumDental ImplantsZirconiumYttriumyttria stabilized tetragonal zirconia

Autor:innen und Institutionen

  • Department of Operative Dentistry, Endodontics and Dental Materials, Bauru School of Dentistry, University of São Paulo (USP), Bauru, Brazil.
  • Centre for Simulation in Bioengineering, Biomechanics and Biomaterials (CS3B), Department of Mechanical Engineering, School of Engineering of Bauru, São Paulo State University (UNESP), Bauru, Brazil.
  • Department of Prosthodontics and Periodontics, Bauru School of Dentistry, University of São Paulo (USP), Bauru, Brazil.
  • Department of Prosthodontics, Positivo University, Curitiba, Brazil.

ORCID-Profile: Bruno Agostinho Hernandez

Zitieren

APA

Chase-Diaz, M., Agostinho Hernandez, B., Minim, P. R., Mosquim, V., Rezende, C. E. E., Rubo, J. H., Capello Sousa, E. A., & Sanches Borges, A. F. (2026). Biomechanical comparison between Y-TZP and titanium dental implants using finite element analysis. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 240(8), 782-794. https://doi.org/10.1177/09544119261467474

Vancouver

Chase-Diaz M, Agostinho Hernandez B, Minim PR, Mosquim V, Rezende CEE, Rubo JH, et al. Biomechanical comparison between Y-TZP and titanium dental implants using finite element analysis. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine. 2026;240(8):782-794. doi:10.1177/09544119261467474

BibTeX
@article{ChaseDiaz2026,
  author = {Chase-Diaz, Melody and Agostinho Hernandez, Bruno and Minim, Pedro Rodrigues and Mosquim, Victor and Rezende, Carlos Eduardo Edwards and Rubo, José Henrique and Capello Sousa, Edson Antonio and Sanches Borges, Ana Flávia},
  title = {Biomechanical comparison between Y-TZP and titanium dental implants using finite element analysis},
  journal = {Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine},
  year = {2026},
  volume = {240},
  number = {8},
  pages = {782--794},
  doi = {10.1177/09544119261467474}
}
Kostenlos starten →