Objective Assessment of Pancreatic Microvascular Density Using Computer-Assisted Detective Flow Imaging Endoscopic Ultrasonography
Endoscopy · 01.06.2026 · 58 (S 03 S 03) · S202-S203
DOI: 10.1055/s-0046-1820971 ↗Kurz gefasst
Fachartikel in der Zeitschrift Endoscopy, erschienen am 01.06.2026. Verfasst von C Robles-Medranda und 19 weiteren Autor:innen.
Abstract (Originalsprache)
Aims
Detective flow imaging (DFI) is an emerging endoscopic ultrasound (EUS) modality capable of visualizing low-velocity microvascular flow without contrast agents [ 1 ]. While qualitative assessment of pancreatic vascularity has been explored [ 1 ] [ 2 ] [ 3 ] [ 4 ], quantitative metrics such as the number of vessels are insufficient. Automated vessel-detection using computer-assisted detection (CADe) software may allow objective measurement of microvascular density, potentially distinguishing healthy pancreas from inflammatory or neoplastic pathology. We aim to evaluate the diagnostic accuracy of a CADe developed for quantification of fine vessels within the pancreas during real-time EUS.
Methods
A prospective study including consecutive adult patients undergoing EUS was performed between June 2024 and October 2025. The pancreas was assessed using DFI. Real-time CADe software analyzed live DFI images, detecting and counting fine vessels. Average fine vessel count (AVC) was defined as the mean vessel count detected by the CADe during the procedure. Ten external physicians, divided into senior (40%) and fellow (60%) endoscopists, evaluated 11 randomly selected EUS-DFI videos to provide vessel counts and categorical interpretation. Intra-class correlation (ICC) and interobserver agreement (IOA) for interpretation were calculated.
Results
Sixty-five participants were included (Inflammatory: 35; Neoplastic: 17; Healthy: 13). Mean age was 53.5±15.0, 66.2±15.9 and 42.2±16.1 (p .05), jaundice was more common in the neoplastic lesions (p=.03) (Table 1). CADe provided a median AVC of 13.0 (10-17) for inflammatory conditions, 8.0 (7.0-16.0) for neoplastic, and 4.0 (3.0-6.0) for healthy pancreas (p
Zitieren
APA
Robles-Medranda, C., Valle, R. D., Alcivar-Vasquez, J., Puga-Tejada, M., Cedeno-Veliz, M., Velez-Padilla, J., Mendez, J. C., Pena-Gonell, G., Florescu, M., Voiosu, T., Nebel, J. A., Stumpf, H., Verardo, P., Kunda, R., Quek, S., Koo, C. S., Oregel-Aguilar, V., Tabacelia, D., Arevalo-Mora, M., & Baquerizo-Burgos, J. (2026). Objective Assessment of Pancreatic Microvascular Density Using Computer-Assisted Detective Flow Imaging Endoscopic Ultrasonography. Endoscopy, 58(S 03 S 03), S202-S203. https://doi.org/10.1055/s-0046-1820971
Vancouver
Robles-Medranda C, Valle RD, Alcivar-Vasquez J, Puga-Tejada M, Cedeno-Veliz M, Velez-Padilla J, et al. Objective Assessment of Pancreatic Microvascular Density Using Computer-Assisted Detective Flow Imaging Endoscopic Ultrasonography. Endoscopy. 2026;58(S 03 S 03):S202-S203. doi:10.1055/s-0046-1820971
BibTeX
@article{RoblesMedranda2026,
author = {Robles-Medranda, C and Valle, R Del and Alcivar-Vasquez, J and Puga-Tejada, M and Cedeno-Veliz, M and Velez-Padilla, J and Mendez, J C and Pena-Gonell, G and Florescu, M and Voiosu, T and Nebel, J A and Stumpf, H and Verardo, P and Kunda, R and Quek, S and Koo, C S and Oregel-Aguilar, V and Tabacelia, D and Arevalo-Mora, M and Baquerizo-Burgos, J},
title = {Objective Assessment of Pancreatic Microvascular Density Using Computer-Assisted Detective Flow Imaging Endoscopic Ultrasonography},
journal = {Endoscopy},
year = {2026},
volume = {58},
number = {S 03 S 03},
pages = {S202--S203},
doi = {10.1055/s-0046-1820971}
}
EUVIMED