Detective Flow Imaging vs Contrast-Enhanced Endoscopic Ultrasonography in solid pancreatic lesions
Endoscopy · 01.04.2024 · 56 (S 02 S 02) · S347
DOI: 10.1055/s-0044-1783547 ↗Kurz gefasst
Fachartikel in der Zeitschrift Endoscopy, erschienen am 01.04.2024. Verfasst von M. V. Mulqui und 7 weiteren Autor:innen.
Abstract (Originalsprache)
Aims
Detective flow imaging endoscopic ultrasonography (DFI-EUS) is a new technology that detects fine vessels and low-flow velocity without contrast agents, used in real time during EUS, with a better resolution compared to usual technologies such as color-Doppler and eFLOW. The aim of this study was to compare DFI-EUS with the technique of contrast-enhanced endoscopic ultrasonography (CE-EUS) for the evaluation of vascularization in solid pancreatic lesions.
Methods
In this retrospective single-center study, we randomly selected patients who underwent EUS for the initial management of a pancreatic mass, between February 2021 and December 2022. We included patients older than 18 years old, who had a pancreatic mass visualized by EUS, with recorded images of their assessment in DFI-EUS and CE-EUS techniques with a histological diagnosis confirming malignant tumors or a minimum of 1-year follow-up for benign lesions. Exclusion criteria included cystic tumors, lesions non-measurable by EUS, lack of a lesion biopsy, or loss to follow-up. The analysis involved simultaneous image readings by two endoscopists. The primary objective was to evaluate the accuracy of DFI-EUS compared to CE-EUS in assessing microvasculature in solid pancreatic lesions.
Results
One hundred and twenty-seven patients were initially selected, of whom 20 were subsequently excluded (14 due to cystic lesions, 3 not biopsied, and 3 lost to follow-up). Of the 107 patients included, histological diagnosis revealed 69 cases (64.4%) of pancreatic adenocarcinoma, 18 cases (16.8%) of neuroendocrine tumors (NET), and 10 cases (9.4%) of metastases from non-pancreatic cancers. A smaller proportion (9.4%) exhibited other lesions, such as benign lesions, lymphomas, acinar cell carcinoma, and accessory spleen. The incidence of intralesional microvascularization was 43.9% with DFI-EUS and 48.6% with CE-EUS, indicating a positive correlation between the two techniques (p=0.0001). We found that, compared to CE-EUS, DFI-EUS exhibited a sensitivity, specificity, Positive Predictive Value (PPV), and Negative Predictive Value (NPV) of 88.5%, 98.2%, 97.9%, and 90%, respectively, for the detection of intralesional vasculature.
Conclusions
The novel technique DFI-EUS demonstrates a remarkable correlation with CE-EUS, exhibiting high sensitivity and specificity for the assessment of microvascularization in solid pancreatic lesions. This method eliminates the need for a contrast agent, thus carrying no risk of adverse effects. Additionally, it allows for the evaluation of microvasculature across multiple lesions in the same patients, without being time-dependent, as observed with CE-EUS. Assessing the cost-benefit ratio of DFI-EUS would be of interest to determine its utility in recommendations for the evaluation of solid pancreatic lesions. Publication History Article published online: 15 April 2024 © 2024. European Society of Gastrointestinal Endoscopy. All rights reserved. Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany
Zitieren
APA
Mulqui, M. V., Caillol, F., Ratone, J. P., Hoibian, S., Dahel, Y., Meunier, E., Archimbaud, C., & Giovannini, M. (2024). Detective Flow Imaging vs Contrast-Enhanced Endoscopic Ultrasonography in solid pancreatic lesions. Endoscopy, 56(S 02 S 02), S347. https://doi.org/10.1055/s-0044-1783547
Vancouver
Mulqui MV, Caillol F, Ratone JP, Hoibian S, Dahel Y, Meunier E, et al. Detective Flow Imaging vs Contrast-Enhanced Endoscopic Ultrasonography in solid pancreatic lesions. Endoscopy. 2024;56(S 02 S 02):S347. doi:10.1055/s-0044-1783547
BibTeX
@article{Mulqui2024,
author = {Mulqui, M. V. and Caillol, F. and Ratone, J. P. and Hoibian, S. and Dahel, Y. and Meunier, E. and Archimbaud, C. and Giovannini, M.},
title = {Detective Flow Imaging vs Contrast-Enhanced Endoscopic Ultrasonography in solid pancreatic lesions},
journal = {Endoscopy},
year = {2024},
volume = {56},
number = {S 02 S 02},
pages = {S347},
doi = {10.1055/s-0044-1783547}
}
EUVIMED