EUVIMEDEUVIMED entdecken
Crossref

Artificial Intelligence-Assisted Detective Flow Imaging Enables Objective Microvascular Quantification in Healthy and Pathologic Liver during Endoscopic Ultrasound

C Robles-Medranda, R Del Valle, J Alcivar-Vasquez, M Puga-Tejada, M Cedeno-Veliz, J Velez-Padilla, G Pena-Gonell, J C Mendez, M Florescu, T Voiosu, J A Nebel, H Stumpf und 8 weitere

Endoscopy · 01.06.2026 · 58 (S 03 S 03) · S203-S204

DOI: 10.1055/s-0046-1820973 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Endoscopy, erschienen am 01.06.2026. Verfasst von C Robles-Medranda und 19 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Aims

Contrast-enhanced endoscopic ultrasound (CE-EUS) provides high-resolution assessment of hepatic microvascularity but requires contrast agents and remains largely qualitative [ 1 ] [ 2 ]. Detective flow imaging (DFI) is a novel EUS modality capable of visualizing low-velocity microvascular flow without contrast [ 3 ]; however, its application in liver evaluation is limited. We aimed to evaluate a real-time AI-based vessel-detection algorithm for objective quantification of microvascular density to distinguish between healthy and pathological liver tissue.

Methods

A prospective study including consecutive adult patients undergoing EUS was performed between June 2024 and October 2025. The liver was assessed using DFI. Real-time CADe software analyzed live DFI images, detecting and counting fine vessels. Average fine vessel count (AVC) was defined as the mean vessel count detected by the CADe during the procedure. Ten external physicians, divided into senior (40%) and fellow (60%) endoscopists, evaluated 10 randomly selected EUS-DFI videos to provide vessel counts and categorical interpretation. Intra-class correlation (ICC) and interobserver agreement (IOA) were calculated.

Results

Sixty participants were included (Pathological: 48; Healthy: 12). Mean age was 59.7±13.6 and 52.0±16.0 (p>.05), and 58.3% were female (p=.512). The most common pathology was alcoholic liver disease, and 68.8% of cases had mild liver disease (Child-Pugh A) (Table 1). CADe provided an AVC of 13.6±5.6 in pathologic and 6.2±7.2 for healthy liver (p

Zitieren

APA

Robles-Medranda, C., Valle, R. D., Alcivar-Vasquez, J., Puga-Tejada, M., Cedeno-Veliz, M., Velez-Padilla, J., Pena-Gonell, G., Mendez, J. C., Florescu, M., Voiosu, T., Nebel, J. A., Stumpf, H., Verardo, P., Kunda, R., Quek, S., Koo, C. S., Oregel-Aguilar, V., Tabacelia, D., Arevalo-Mora, M., & Baquerizo-Burgos, J. (2026). Artificial Intelligence-Assisted Detective Flow Imaging Enables Objective Microvascular Quantification in Healthy and Pathologic Liver during Endoscopic Ultrasound. Endoscopy, 58(S 03 S 03), S203-S204. https://doi.org/10.1055/s-0046-1820973

Vancouver

Robles-Medranda C, Valle RD, Alcivar-Vasquez J, Puga-Tejada M, Cedeno-Veliz M, Velez-Padilla J, et al. Artificial Intelligence-Assisted Detective Flow Imaging Enables Objective Microvascular Quantification in Healthy and Pathologic Liver during Endoscopic Ultrasound. Endoscopy. 2026;58(S 03 S 03):S203-S204. doi:10.1055/s-0046-1820973

BibTeX
@article{RoblesMedranda2026,
  author = {Robles-Medranda, C and Valle, R Del and Alcivar-Vasquez, J and Puga-Tejada, M and Cedeno-Veliz, M and Velez-Padilla, J and Pena-Gonell, G and Mendez, J C and Florescu, M and Voiosu, T and Nebel, J A and Stumpf, H and Verardo, P and Kunda, R and Quek, S and Koo, C S and Oregel-Aguilar, V and Tabacelia, D and Arevalo-Mora, M and Baquerizo-Burgos, J},
  title = {Artificial Intelligence-Assisted Detective Flow Imaging Enables Objective Microvascular Quantification in Healthy and Pathologic Liver during Endoscopic Ultrasound},
  journal = {Endoscopy},
  year = {2026},
  volume = {58},
  number = {S 03 S 03},
  pages = {S203--S204},
  doi = {10.1055/s-0046-1820973}
}
Kostenlos starten →