F-18-PSMA using a next generation 148 cm LAFOV PET/CT: Effect of scan duration on lesion signal and background noise

D Weiberg, P Rath, S Kröhn, L R Nikoukar, A-M Uhlemann, K Henning, S Ziegler, F Bengel

Nuklearmedizin - NuclearMedicine · 01.04.2026 · 65 (02) · 178

DOI: 10.1055/s-0046-1818384 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Nuklearmedizin - NuclearMedicine, erschienen am 01.04.2026. Verfasst von D Weiberg und 7 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Ziel/Aim: Next generation long axial field of view (LAFOV) PET/CT scanners offer much higher molecular sensitivity and higher spatial resolution, enabling shorter acquisition time as compared to previous standard axial field of view (SAFOV) scanners. However, tracer-specific acquisition protocols are not yet standardized. We evaluated the effect of novel reconstruction techniques and shorter scan duration on static image quality of F-18-PSMA studies. Methodik/Methods: Using the Panorama GS 148cm LAFOV PET/CT (United Imaging Healthcare), we evaluated the data of 10 patients with prostate cancer, who underwent a 5 min list-mode F-18-JK-PSMA-7 scan (standard dose 3 MBq/kg bodyweight) 90min p.i. and low-dose CT for attenuation correction. List-mode data were re-sampled to 300, 150, 60, 30 and 15 sec static datasets. Each was reconstructed using standard OSEM iterative algorithm and a manufacturer-provided advanced iterative algorithm (hyper iterative, HI). Lesion signal strength was measured by SUVpeak and SUVmax in 3 lesions per patient, and change was defined relative to OSEM 300 sec as reference. Automated CT-based organ segmentation was employed and Coefficient of Variation (CoV) for SUVmean of the lesion-free liver was used as a measure of background noise. Ergebnisse/Results: Independent of scan duration, CoV remains stable from 27 to 30% for OSEM reconstruction and from 26 to 28% for HI reconstruction. Relative change of lesional SUVpeak ratio was low at 1 to 4% between all scan durations for both reconstruction methods. For SUVmax, shorter OSEM scan duration increases relative change up to 8%, while HI reconstruction shows higher lesional SUVmax ratios up to 13% for longer scan durations. Schlussfolgerungen/Conclusion: For F-18-PSMA imaging with standard injected activity, LAFOV PET enables a reduction of acquisition time down to 15 sec without increase of background noise or loss of lesion signal strength measured by SUVpeak. Alternatively, an imaging protocol with 25% lower injected activity and 1 min scan duration could be chosen. SUVmax is more susceptible to different scan durations and reconstruction algorithms and should thus be used with care for SUV-based image analysis. Publication History Article published online: 02 April 2026 © 2026. Thieme. All rights reserved. Georg Thieme Verlag KG Oswald-Hesse-Straße 50, 70469 Stuttgart, Germany

Zitieren

APA

Weiberg, D., Rath, P., Kröhn, S., Nikoukar, L. R., Uhlemann, A., Henning, K., Ziegler, S., & Bengel, F. (2026). F-18-PSMA using a next generation 148 cm LAFOV PET/CT: Effect of scan duration on lesion signal and background noise. Nuklearmedizin - NuclearMedicine, 65(02), 178. https://doi.org/10.1055/s-0046-1818384

Vancouver

Weiberg D, Rath P, Kröhn S, Nikoukar LR, Uhlemann A, Henning K, et al. F-18-PSMA using a next generation 148 cm LAFOV PET/CT: Effect of scan duration on lesion signal and background noise. Nuklearmedizin - NuclearMedicine. 2026;65(02):178. doi:10.1055/s-0046-1818384

BibTeX
@article{Weiberg2026,
  author = {Weiberg, D and Rath, P and Kröhn, S and Nikoukar, L R and Uhlemann, A-M and Henning, K and Ziegler, S and Bengel, F},
  title = {F-18-PSMA using a next generation 148 cm LAFOV PET/CT: Effect of scan duration on lesion signal and background noise},
  journal = {Nuklearmedizin - NuclearMedicine},
  year = {2026},
  volume = {65},
  number = {02},
  pages = {178},
  doi = {10.1055/s-0046-1818384}
}
Kostenlos starten →