Determining the Effect of Scan Duration and Reconstruction Algorithm on Lesion Signal Strength and Background Noise for Ga-68-DOTATATE Studies Using a Next Generation 148cm LAFOV PET System
Nuklearmedizin - NuclearMedicine · 01.04.2026 · 65 (02) · 158-159
DOI: 10.1055/s-0046-1818329 ↗Kurz gefasst
Fachartikel in der Zeitschrift Nuklearmedizin - NuclearMedicine, erschienen am 01.04.2026. Verfasst von L R Nikoukar und 7 weiteren Autor:innen.
Abstract (Originalsprache)
Ziel/Aim: In recent years, long axial field of view (LAFOV) PET/CT has gained significant attention and is being used in clinical settings. However, optimal scan protocols and reconstruction methods have yet to be established. An additional challenge is that protocols based on Ga-68-labeled tracers typically differ from F-18 tracers regarding image noise and target lesion signal strength. This preliminary study provides insight into this matter. Methodik/Methods: We evaluated data from 6 patients undergoing Ga-68-DOTATATE-PET/CT in a Panorama GS 148cm LAFOV System (United Imaging Healthcare). The patients were injected the standard dose of 2 MBq/Kg body weight and low-dose CT was performed for attenuation correction. List-mode data were acquired 30 min p.i. and were re-sampled to 300, 150, 60, 30 and 15 sec static datasets. Each was reconstructed using standard OSEM iterative algorithm and a manufacturer-provided advanced iterative algorithm (hyper-iterative, HI). Lesion signal strength was measured by SUV (body weight) in up to 3 lesions per patient, and change was defined relative to OSEM 300s as reference. Automated CT-based organ segmentation was employed and Coefficient of Variation (CoV) for SUV of the liver was used as a measure of background noise. Ergebnisse/Results: The average background noise increased for shorter scan durations in OSEM reconstruction protocol from 8% to 13% and remained stable in HI reconstruction protocol between 9% and 8%. The relative changes of lesion SUV parameters with different scan durations showed different patterns regarding SUVpeak, mean and max. The SUVpeak and SUVmean showed the least changes with scan duration, on average between 0.96 and 1.12, while the average SUVmax fluctuated between 0.99 and 1.27. Schlussfolgerungen/Conclusion: For Ga-68-based imaging, background noise remains stable in the HI reconstruction protocol while increasing with shorter scan durations in the OSEM reconstruction protocol. Regarding the lesion signal intensity, the reduction of scan duration to e.g. 60 sec seems feasible for SUV mean or peak measurements using the HI algorithm. However, values yielded from OSEM reconstruction, especially SUVmax, should be interpreted more cautiously, bearing in mind that SUVmax is more susceptible to these changes. Publication History Article published online: 02 April 2026 © 2026. Thieme. All rights reserved. Georg Thieme Verlag KG Oswald-Hesse-Straße 50, 70469 Stuttgart, Germany
Zitieren
APA
Nikoukar, L. R., Rath, P., Ziegler, S., Weiberg, D., Kröhn, S., Henning, K., Uhlemann, A., & Bengel, F. (2026). Determining the Effect of Scan Duration and Reconstruction Algorithm on Lesion Signal Strength and Background Noise for Ga-68-DOTATATE Studies Using a Next Generation 148cm LAFOV PET System. Nuklearmedizin - NuclearMedicine, 65(02), 158-159. https://doi.org/10.1055/s-0046-1818329
Vancouver
Nikoukar LR, Rath P, Ziegler S, Weiberg D, Kröhn S, Henning K, et al. Determining the Effect of Scan Duration and Reconstruction Algorithm on Lesion Signal Strength and Background Noise for Ga-68-DOTATATE Studies Using a Next Generation 148cm LAFOV PET System. Nuklearmedizin - NuclearMedicine. 2026;65(02):158-159. doi:10.1055/s-0046-1818329
BibTeX
@article{Nikoukar2026,
author = {Nikoukar, L R and Rath, P and Ziegler, S and Weiberg, D and Kröhn, S and Henning, K and Uhlemann, A-M and Bengel, F},
title = {Determining the Effect of Scan Duration and Reconstruction Algorithm on Lesion Signal Strength and Background Noise for Ga-68-DOTATATE Studies Using a Next Generation 148cm LAFOV PET System},
journal = {Nuklearmedizin - NuclearMedicine},
year = {2026},
volume = {65},
number = {02},
pages = {158--159},
doi = {10.1055/s-0046-1818329}
}
EUVIMED