Eyes wide open: MOSE Performance in EUS FNB
Endoscopy · 01.04.2024 · 56 (S 02 S 02) · S155
DOI: 10.1055/s-0044-1783029 ↗Kurz gefasst
Fachartikel in der Zeitschrift Endoscopy, erschienen am 01.04.2024. Verfasst von A. C. Bravo und 8 weiteren Autor:innen.
Abstract (Originalsprache)
Aims
Endoscopic ultrasound fine needle biopsy (EUS-FNB) is the preferred method for sampling solid lesions in the digestive wall or adjacent organs. Strategies to enhance its efficacy have been explored, with recent studies indicating that Macroscopic On-Site Evaluation (MOSE) by an echoendoscopist can be comparable to Rapid On-site Evaluation (ROSE) by an anatomopathologist. This study aims to assess the performance of MOSE in EUS-FNB, specifically using the 22G Franseen needle.
Methods
Single-center retrospective cohort study, including all consecutive patients who underwent EUS-FNB with a 22G Franseen needle to characterize solid lesions, with a standardized description of MOSE, between April 2021 and September 2023. The performance of MOSE was evaluated, with diagnostic yield being considered when obtaining of diagnostic cytology, and diagnostic accuracy as the quotient between correctly diagnosed cases and the total number of cases. The final diagnosis was made based on the pathology of the surgical specimen or clinical/imaging evolution. Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were calculated considering malignant and benign lesions as positive and negative results, respectively.
Results
57 patients were included, with 53% men, and 60 punctures were performed (57% pancreatic, 25% subepithelial, 3% hepatic/biliary, 3% lymph node, 3% adrenal, 8% perirectal). Median lesion size was 30 mm (inter-quartile range (IQR) 20-40 mm), with a median of 3 (IQR 2-4) passes. Echoendoscopist detected filamentary material in 100% of the exams. White fragments were obtained in 91% of exams, with a maximum median dimension of 5 mm (IQR 3-10 mm). There was a diagnostic yield in 92% of the exams, with a diagnostic accuracy of 90%. Sensitivity, specificity, PPV and NPV were, respectively, 97%, 100%, 100% and 94%. Self-limited hemorrhage was found in 1 of the exams. Fragments≥4 mm were associated with a higher diagnostic yield (p=0.01), unlike the color of the fragment.
Conclusions
This study suggests that MOSE utilization during EUS-FNB is associated with a substantial diagnostic yield. Fragments≥4 mm are associated with a high likelihood of obtaining a diagnostic cytology, and ensuring high diagnostic accuracy, sensitivity, specificity, PPV and NPV. Publication History Article published online: 15 April 2024 © 2024. European Society of Gastrointestinal Endoscopy. All rights reserved. Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany
Zitieren
APA
Bravo, A. C., Nascimento, C., Morão, B., Revés, J., Abreu, B., Bargas, A., Loureiro, R., Glória, L., & Fidalgo, C. (2024). Eyes wide open: MOSE Performance in EUS FNB. Endoscopy, 56(S 02 S 02), S155. https://doi.org/10.1055/s-0044-1783029
Vancouver
Bravo AC, Nascimento C, Morão B, Revés J, Abreu B, Bargas A, et al. Eyes wide open: MOSE Performance in EUS FNB. Endoscopy. 2024;56(S 02 S 02):S155. doi:10.1055/s-0044-1783029
BibTeX
@article{Bravo2024,
author = {Bravo, A. C. and Nascimento, C. and Morão, B. and Revés, J. and Abreu, B. and Bargas, A. and Loureiro, R. and Glória, L. and Fidalgo, C.},
title = {Eyes wide open: MOSE Performance in EUS FNB},
journal = {Endoscopy},
year = {2024},
volume = {56},
number = {S 02 S 02},
pages = {S155},
doi = {10.1055/s-0044-1783029}
}
EUVIMED