Abstract (Originalsprache)

Aims

The diagnostic performance of endoscopic ultrasound-guided tissue acquisition (EUS-TA) for diagnosis of solid pancreatic lesions (SPLs) may be impacted by small tumor size. We aimed to compare the diagnostic yield of EUS-guided fine-needle aspiration (FNA) and biopsy (FNB) in SPLs with a diameter≤15 mm.

Methods

Consecutive patients who underwent EUS-TA for SPLs≤15 mm between January 2015 and December 2022 in a tertiary referral center were retrospectively evaluated. Primary endpoint was diagnostic accuracy. Final diagnosis was based on surgical pathology or disease evolution after a minimum follow-up of 6 months. ROSE was never available. Inadequate samples were all considered as false negative for the study purpose. Secondary outcomes included sample adequacy, factors impacting accuracy, and safety. Moreover, the feasibility of Ki-67 index in the subgroup of patients with pancreatic neuroendocrine tumours (Pan-NETs) was evaluated.

Results

We included 368 patients (male, 52.4%; mean age 60.2 years) who underwent FNA in 72 cases and FNB in 296. The mean size of SPLs was 11.9±2.6 mm. 93 (25.3%) patients underwent surgery. A benign condition was eventually diagnosed in 13.9% of cases, whereas a malignant lesion in 84.8%, including 206 PanNETs, 73 pancreatic adenocarcinoma and 26 metastases. FNB outperformed FNA in terms of diagnostic accuracy (89.8% vs 79.1%, p=0.013) and sample adequacy (95.9% vs 86.1%, p

Zitieren

APA

Bellocchi, M. C. C., Bernuzzi, M., Brillo, A., Bernardoni, L., Amodio, A., Pretis, N. D., Frulloni, L., Gabbrielli, A., & Crinò, S. F. (2024). EUS-FNA versus EUS-FNB in pancreatic solid lesions≤15 mm. Endoscopy, 56(S 02 S 02), S40. https://doi.org/10.1055/s-0044-1782770

Vancouver

Bellocchi MCC, Bernuzzi M, Brillo A, Bernardoni L, Amodio A, Pretis ND, et al. EUS-FNA versus EUS-FNB in pancreatic solid lesions≤15 mm. Endoscopy. 2024;56(S 02 S 02):S40. doi:10.1055/s-0044-1782770

BibTeX
@article{Bellocchi2024,
  author = {Bellocchi, M. C. Conti and Bernuzzi, M. and Brillo, A. and Bernardoni, L. and Amodio, A. and Pretis, N. De and Frulloni, L. and Gabbrielli, A. and Crinò, S. F.},
  title = {EUS-FNA versus EUS-FNB in pancreatic solid lesions≤15 mm},
  journal = {Endoscopy},
  year = {2024},
  volume = {56},
  number = {S 02 S 02},
  pages = {S40},
  doi = {10.1055/s-0044-1782770}
}
Kostenlos starten →