EUVIMEDEUVIMED entdecken
Crossref

EUS-FNA versus EUS-FNB for solid pancreatic masses: diagnostic performance, needle passes and predictors of failure

H Elommal, O Elmqaddem, H Koulali, A Zazour, G Kharrasse, Z Ismaili

Endoscopy · 01.06.2026 · 58 (S 03 S 03) · S649

DOI: 10.1055/s-0046-1821892 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Endoscopy, erschienen am 01.06.2026. Verfasst von H Elommal und 5 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Aims

To compare the diagnostic performance (adequacy), number of needle passes and safety of endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) versus fine-needle biopsy (EUS-FNB) for solid pancreatic masses, and to identify predictors of non-diagnostic sampling.

Methods

Single-centre retrospective study including all pancreatic EUS-FNA/FNB procedures from a local database (FNA n=187, FNB n=34).The primary endpoint was diagnostic adequacy (conclusive vs non-conclusive). Secondary endpoints were number of passes and adverse events within 7 days. Proportions were compared using χ²/Fisher’s exact tests and non-parametric variables using the Mann–Whitney test. A multivariable logistic regression model (outcome: non-conclusive result) included sampling technique (FNB vs FNA), lesion size (>3 cm), location (head vs body/tail), puncture route (trans-duodenal vs trans-gastric) and number of passes. Because a reference standard (surgery/biopsy/follow-up) was not available, diagnostic performance was assessed through adequacy rather than sensitivity/specificity.

Results

Adequacy was 73.3% (137/187) for FNA vs 82.4% (28/34) for FNB (p=0.365; OR 1.70, 95% CI 0.66–4.36).Median passes (IQR) were 2 (2–3) for FNA vs 1 (1–2) for FNB (p 3 cm 75.3% vs

Zitieren

APA

Elommal, H., Elmqaddem, O., Koulali, H., Zazour, A., Kharrasse, G., & Ismaili, Z. (2026). EUS-FNA versus EUS-FNB for solid pancreatic masses: diagnostic performance, needle passes and predictors of failure. Endoscopy, 58(S 03 S 03), S649. https://doi.org/10.1055/s-0046-1821892

Vancouver

Elommal H, Elmqaddem O, Koulali H, Zazour A, Kharrasse G, Ismaili Z. EUS-FNA versus EUS-FNB for solid pancreatic masses: diagnostic performance, needle passes and predictors of failure. Endoscopy. 2026;58(S 03 S 03):S649. doi:10.1055/s-0046-1821892

BibTeX
@article{Elommal2026,
  author = {Elommal, H and Elmqaddem, O and Koulali, H and Zazour, A and Kharrasse, G and Ismaili, Z},
  title = {EUS-FNA versus EUS-FNB for solid pancreatic masses: diagnostic performance, needle passes and predictors of failure},
  journal = {Endoscopy},
  year = {2026},
  volume = {58},
  number = {S 03 S 03},
  pages = {S649},
  doi = {10.1055/s-0046-1821892}
}
Kostenlos starten →