EUVIMEDEUVIMED entdecken
Crossref

Improved Posterior Slope of the Tibial Component in Unicompartmental Knee Arthroplasty Using an Offset Adjustment Method

Yukio Akasaki iD, Satoshi Hamai iD, Shinya Kawahara iD, Taishi Sato, Yasuharu Nakashima

The Journal of Knee Surgery · 01.09.2026 · 39 (11) · 608-612

DOI: 10.1055/a-2835-3391 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Journal of Knee Surgery, erschienen am 01.09.2026. Verfasst von Yukio Akasaki und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedic Surgery, Kyushu University, Higashi-ku, Fukuoka, Japan. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Knee, Tibia, Knee Prosthesis, Osteoarthritis, Knee.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

AbstractAchieving a consistent patient-specific posterior tibial slope (PTS) in unicompartmental knee arthroplasty (UKA) is critical. Current methods lack standardization, and the influence of offset adjustments on PTS reproducibility in UKA has not been studied. This study aimed to investigate the reproducibility of patient-specific PTS using a jig that adjusts the offset of the proximal and distal tibial rods in UKA. Sixty-four knees underwent UKA with the offset adjustment jig, and 64 served as controls. Preoperative and postoperative PTS were measured on lateral knee radiographs. Statistical analyses compared changes in PTS and outliers between groups. The offset adjustment group showed a moderate correlation (R = 0.53, p < 0.001) between preoperative and postoperative PTS, compared to a weak correlation (R = 0.32, p = 0.009) in the control group. The absolute PTS change was statistically significantly smaller in the offset adjustment group (1.2 degrees vs. 1.9 degrees, p = 0.009). Fewer outliers with PTS changes of 2 degrees or more were observed in the offset adjustment group. Using an offset adjustment jig in UKA significantly improves the reproducibility of patient-specific PTS, reducing deviations and potential biomechanical issues. This method is practical, cost-effective, and compatible with various implant models, offering a reliable solution for achieving precise PTS alignment without extending surgical time.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Arthroplasty, Replacement, KneeTibiaKnee ProsthesisOsteoarthritis, KneeKnee JointHumansReproducibility of ResultsFemaleAgedMaleMiddle AgedRadiography

Autor:innen und Institutionen

  • Department of Orthopaedic Surgery, Kyushu University, Higashi-ku, Fukuoka, Japan.

ORCID-Profile: Yukio Akasaki, Satoshi Hamai, Shinya Kawahara

Zitieren

APA

Akasaki, Y., Hamai, S., Kawahara, S., Sato, T., & Nakashima, Y. (2026). Improved Posterior Slope of the Tibial Component in Unicompartmental Knee Arthroplasty Using an Offset Adjustment Method. The Journal of Knee Surgery, 39(11), 608-612. https://doi.org/10.1055/a-2835-3391

Vancouver

Akasaki Y, Hamai S, Kawahara S, Sato T, Nakashima Y. Improved Posterior Slope of the Tibial Component in Unicompartmental Knee Arthroplasty Using an Offset Adjustment Method. The Journal of Knee Surgery. 2026;39(11):608-612. doi:10.1055/a-2835-3391

BibTeX
@article{Akasaki2026,
  author = {Akasaki, Yukio and Hamai, Satoshi and Kawahara, Shinya and Sato, Taishi and Nakashima, Yasuharu},
  title = {Improved Posterior Slope of the Tibial Component in Unicompartmental Knee Arthroplasty Using an Offset Adjustment Method},
  journal = {The Journal of Knee Surgery},
  year = {2026},
  volume = {39},
  number = {11},
  pages = {608--612},
  doi = {10.1055/a-2835-3391}
}
Kostenlos starten →