EUVIMEDEUVIMED entdecken
Crossref

Posterior tibial slope after total knee arthroplasty is not reproducible or consistent

Ekin Barış Demir, Fatih Barça, Mert Uçak, Halis Atıl Atilla, Mutlu Akdoğan, Yalım Ateş

The Knee · 2025

DOI: 10.1016/j.knee.2025.01.006 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Knee, 2025. Verfasst von Ekin Barış Demir und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopedics and Traumatology, Ankara Etlik City Hospital, Ankara, Turkey. Electronic address: ekinbarisdemir@hotmail.com. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Knee, Tibia, Knee Prosthesis, Osteoarthritis, Knee. Die Arbeit nennt 38 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Our aim was to compare posterior tibial slope (PTS) values, distribution, deviation from manufacturer's recommended value and restoration of this value in total knee arthroplasty (TKA) with tibial component placement using intramedullary (IM) and extramedullary (EM) methods, and to analyze factors affecting these values. METHODS: A total of 151 knees operated with Zimmer-Biomet NexGen® LPS Fixed Bearing Knee TKA between 2022 and 2024 were retrospectively investigated. Knees were grouped by method of tibial component placement (IM or EM). Pre-operative descriptive data, postoperative PTS, scatteredness of PTS, difference between pre-operative and postoperative PTS, deviation from 7° which was claimed by the manufacturer and rate of outliers were compared between groups. Factors that might affect postoperative PTS in the EM group were analyzed. RESULTS: Ninety-five knees (62.9%) in the EM group and 56 knees (37.1%) in the IM group were analyzed. Mean PTS decreased from 8.8 ± 3.5° to 6.7 ± 2.7° (P < 0.001) in the EM group, and from 10 ± 4.1° to 4.9 ± 2.6° (P < 0.001) in the IM group. Postoperative PTS was significantly lower in the IM group (P < 0.001). Mean deviation from 7° claimed by the manufacturer was 2.4 ± 1.4° for the EM group and 2.8 ± 1.8° for the IM group (P = 0.14). In 15 of 151 patients (9.9%), postoperative PTS was above 10°. Linear regression analysis revealed a moderate effect of pre-operative PTS and weight in the EM group. CONCLUSIONS: Although not statistically significant, the EM method is closer to the manufacturer's recommendation for sagittal alignment. However, both groups had a wide range of PTS and a large number of outliers. Both methods are not reliable in terms of PTS reproducibility and consistency.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Arthroplasty, Replacement, KneeTibiaKnee ProsthesisOsteoarthritis, KneeKnee JointHumansRetrospective StudiesMaleFemaleAgedMiddle AgedReproducibility of ResultsAged, 80 and over

Stichwörter der Autor:innen

Posterior tibial slopeSagittal alignmentTibial componentTotal knee arthroplasty

Autor:innen und Institutionen

  • Department of Orthopedics and Traumatology, Ankara Etlik City Hospital, Ankara, Turkey. Electronic address: ekinbarisdemir@hotmail.com.
  • Department of Orthopedics and Traumatology, Ankara Etlik City Hospital, Ankara, Turkey.

Zitieren

APA

Demir, E. B., Barça, F., Uçak, M., Atilla, H. A., Akdoğan, M., & Ateş, Y. (2025). Posterior tibial slope after total knee arthroplasty is not reproducible or consistent. The Knee. https://doi.org/10.1016/j.knee.2025.01.006

Vancouver

Demir EB, Barça F, Uçak M, Atilla HA, Akdoğan M, Ateş Y. Posterior tibial slope after total knee arthroplasty is not reproducible or consistent. The Knee. 2025. doi:10.1016/j.knee.2025.01.006

BibTeX
@article{Demir2025,
  author = {Demir, Ekin Barış and Barça, Fatih and Uçak, Mert and Atilla, Halis Atıl and Akdoğan, Mutlu and Ateş, Yalım},
  title = {Posterior tibial slope after total knee arthroplasty is not reproducible or consistent},
  journal = {The Knee},
  year = {2025},
  doi = {10.1016/j.knee.2025.01.006}
}
Kostenlos starten →