EUVIMEDEUVIMED entdecken
BeobachtungsstudieOpen Access

Accuracy of Preoperative Radiographic Templating Across Four Widely Used Total Knee Arthroplasty Systems

İsa Bolat iD, Mustafa Tekin iD, Jalal İbrahimov iD, Orçin Bozkurt iD

Acta Orthopaedica et Traumatologica Turcica · 2026

DOI: 10.5152/j.aott.2026.25811 ↗

Kurz gefasst

Beobachtungsstudie in der Zeitschrift Acta Orthopaedica et Traumatologica Turcica, 2026. Verfasst von İsa Bolat und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedics and Traumatology, Dörtyol State Hospital, Hatay, Türkiye. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Knee, Osteoarthritis, Knee, Radiography, Preoperative Care. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

This study aimed to evaluate the accuracy of standardized preoperative radiographic templating in predicting femoral and tibial component sizes across four different total knee arthroplasty (TKA) systems in patients undergoing primary TKA for osteoarthritis.

Methods

This retrospective, single-center observational study included 160 knees from 141 patients (mean age of 67.3 - 7.9 years) who underwent primary TKA for osteoarthritis between March 2011 and March 2020. Of the 141 patients, 122 underwent unilateral and 19 underwent bilateral TKA. Four different TKA systems were evaluated, with 40 knees assigned to each implant group. Standardized weight-bearing anteroposterior and lateral knee radiographs were used to measure femoral and tibial dimensions using a picture archiving and communication system (PACS). The primary outcome was the agreement between radiographically predicted and intraoperatively implanted femoral and tibial component sizes. Agreement was assessed using weighted Cohen’s kappa (κ), and interobserver reliability was evaluated using the intraclass correlation coefficient (ICC).

Results

For femoral components, the exact size was predicted in 76.9% of knees, and 96.8% of predictions were within - 1 implant size. For tibial components, the exact size was predicted in 64.4% of knees, and 92.5% were within - 1 implant size. Agreement between predicted and implanted sizes was substantial for femoral components (κ = 0.70, 95% CI, 0.62–0.78) and moderate for tibial components (κ = 0.54, 95% CI, 0.45–0.63). Size discrepancies differed significantly among the four implant systems for both tibial (P = 0.001) and femoral components (P = 0.010). Overall, 94.4% (302/320) of all component size predictions were within - 1 implant size.

Conclusion

Standardized preoperative radiographic templating reliably predicted component size across four different TKA systems, with greater accuracy for femoral than for tibial components. When standardized radiographic acquisition, calibration, and measurement protocols are applied, conventional two-dimensional templating can provide clinically acceptable component-size predictions across different implant designs. These findings support its clinical utility as an accessible and cost-effective method for preoperative planning in primary TKA. Cite this article as: Bolat İ, Tekin M, İbrahimov J, Bozkurt O. Accuracy of standardized preoperative radiographic templating in predicting implant size: a comparative analysis of four widely used total knee arthroplasty systems. Acta Orthop Traumatol Turc., 2026; 60(5), 0811, doi: 10.5152/j.aott.2026.25811.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Arthroplasty, Replacement, KneeOsteoarthritis, KneeRadiographyPreoperative CareKnee ProsthesisKnee JointHumansRetrospective StudiesAgedFemaleReproducibility of ResultsMaleFemurTibiaMiddle Aged

Stichwörter der Autor:innen

ArthroplastyKneePreoperative careProsthesis fittingRadiographyReplacementReproducibility of results

Autor:innen und Institutionen

  • Department of Orthopaedics and Traumatology, Dörtyol State Hospital, Hatay, Türkiye.
  • Department of Orthopaedics and Traumatology, Çukurova University Faculty of Medicine, Adana, Türkiye.
  • Department of Orthopaedics and Traumatology, Karşıyaka State Hospital, Adana, Türkiye.

ORCID-Profile: İsa Bolat, Mustafa Tekin, Jalal İbrahimov, Orçin Bozkurt

Zitieren

APA

Bolat, İ., Tekin, M., İbrahimov, J., & Bozkurt, O. (2026). Accuracy of Preoperative Radiographic Templating Across Four Widely Used Total Knee Arthroplasty Systems. Acta Orthopaedica et Traumatologica Turcica. https://doi.org/10.5152/j.aott.2026.25811

Vancouver

Bolat İ, Tekin M, İbrahimov J, Bozkurt O. Accuracy of Preoperative Radiographic Templating Across Four Widely Used Total Knee Arthroplasty Systems. Acta Orthopaedica et Traumatologica Turcica. 2026. doi:10.5152/j.aott.2026.25811

BibTeX
@article{Bolat2026,
  author = {Bolat, İsa and Tekin, Mustafa and İbrahimov, Jalal and Bozkurt, Orçin},
  title = {Accuracy of Preoperative Radiographic Templating Across Four Widely Used Total Knee Arthroplasty Systems},
  journal = {Acta Orthopaedica et Traumatologica Turcica},
  year = {2026},
  doi = {10.5152/j.aott.2026.25811}
}
Kostenlos starten →