Inter- and intra-individual radiation dose variability in oncologic chest and abdominal computed tomography
RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren · 01.10.2026 · 198 (10) · 1330-1340
DOI: 10.1055/a-2786-2534 ↗Kurz gefasst
Fachartikel in der Zeitschrift RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, erschienen am 01.10.2026. Verfasst von Arian Felix Moradians und 11 weiteren Autor:innen. Beteiligte Einrichtung: University Hospital Essen, Institute of Diagnostic and Interventional Radiology and Neuroradiology, NRW, Germany, Essen. Hauptthemen laut MEDLINE: Radiation Dosage, Tomography, X-Ray Computed, Radiography, Abdominal, Radiography, Thoracic. Die Arbeit nennt 24 Literaturangaben.
Abstract (Originalsprache)
Computed tomography (CT) plays a central role in oncologic imaging, yet repeated examinations contribute substantially to cumulative radiation exposure. This study aimed to evaluate inter- and intra-individual radiation dose variability in chest and abdominal CT and the impact of CT device model and protocol standardization. In this retrospective single-center study, 42441 CT scans from 4986 adult oncologic patients were analyzed. Dose metrics (CTDIvol, DLP, SSDE, effective dose) were extracted using automated dose monitoring. Inter- and intra-individual radiation dose variability was assessed across four CT device models and various protocol subtypes. Intra-individual radiation dose variability was calculated relative to the lowest dose per patient and compared across CT devices and protocol subtypes. Radiation dose varied substantially between devices, with CTDIvol differences of up to 2.4-fold in chest CT (2.98–7.26 mGy) and 1.7-fold in abdominal CT (5.26–8.77 mGy). The median intra-individual radiation dose variability was 93.7% (IQR 19.8–142.0%) in non-contrast chest CT, 66.3% (31.1–105.4%) in contrast-enhanced chest CT, 19.8% (11.8–32.3%) in non-contrast abdominal CT, and 28.2% (16.6–41.0%) in contrast-enhanced abdominal CT. When consecutive scans were performed on the same scanner, intra-individual radiation dose variability decreased to 14.7% (IQR 8.1–33.1%), 18.1% (9.5–31.3%), 11.7% (7.8–19.8%), and 15.3% (8.3–24.7%), respectively, indicating substantial device-specific effects. Significant radiation dose variability persists in oncologic CT, both between and within patients, despite the use of standardized protocols. Device-adapted dose management and consistent device use may improve dose consistency, support optimization in oncologic imaging, and reduce radiation exposure.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- University Hospital Essen, Institute of Diagnostic and Interventional Radiology and Neuroradiology, NRW, Germany, Essen.
- University Hospital Bonn, Department of Diagnostic and Interventional Radiology, Germany, Bonn.
- University Hospital Zurich Institute of Diagnostic Radiology, Institute of Diagnostic Radiology, Switzerland, Zürich.
ORCID-Profile: Arian Felix Moradians, Laura Valentina Klüner, Denise Bos, Marcel Klaus Opitz, Sebastian Zensen
Zitieren
APA
Moradians, A. F., Rosok, D., Serger, R., Klüner, L. V., Drews, M., Behr, F., Salhöfer, L., Bos, D., Forsting, M., Haubold, J., Opitz, M. K., & Zensen, S. (2026). Inter- and intra-individual radiation dose variability in oncologic chest and abdominal computed tomography. RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 198(10), 1330-1340. https://doi.org/10.1055/a-2786-2534
Vancouver
Moradians AF, Rosok D, Serger R, Klüner LV, Drews M, Behr F, et al. Inter- and intra-individual radiation dose variability in oncologic chest and abdominal computed tomography. RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren. 2026;198(10):1330-1340. doi:10.1055/a-2786-2534
BibTeX
@article{Moradians2026,
author = {Moradians, Arian Felix and Rosok, Daniel and Serger, Raya and Klüner, Laura Valentina and Drews, Marcel and Behr, Florian and Salhöfer, Luca and Bos, Denise and Forsting, Michael and Haubold, Johannes and Opitz, Marcel Klaus and Zensen, Sebastian},
title = {Inter- and intra-individual radiation dose variability in oncologic chest and abdominal computed tomography},
journal = {RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren},
year = {2026},
volume = {198},
number = {10},
pages = {1330--1340},
doi = {10.1055/a-2786-2534}
}
EUVIMED