Beobachtungsstudie in der Zeitschrift Journal of Cardiothoracic and Vascular Anesthesia, 2023. Verfasst von Renan A Ferrufino und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Anesthesiology and Perioperative Medicine, Tufts Medical Center, Boston, MA. Hauptthemen laut MEDLINE: Heart-Assist Devices, Heart Failure, Ventricular Dysfunction, Right. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 27 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVES: To evaluate the association of pulmonary artery diameter and pulmonary artery- to-aorta diameter ratio (PA/Ao) with right ventricular failure and mortality within 1 year after left ventricular assist device implantation. DESIGN: This was a retrospective observational study between March 2013 and July 2019. SETTING: The study was conducted at a single, quaternary-care academic center. PARTICIPANTS: Adults (≥18 years old) receiving a durable left ventricular assist device (LVAD). Inclusion if (1) a chest computed tomography scan was performed within 30 days before the LVAD and (2) a right and left heart catheterization was completed within 30 days before the LVAD. INTERVENTIONS: A left ventricular assist device was used for intervention. MEASUREMENTS AND MAIN RESULTS: A total of 176 patients were included in this study. Median PA diameter and PA/Ao ratio were significantly greater in the severe right ventricular failure (RVF) group (p = 0.001, p < 0.001, respectively). Receiver operating characteristic analysis revealed PA/Ao and RVF as predictors for mortality (area under the curve = 0.725 and 0.933, respectively). Logistic regression analysis-predicted probability gave a PA/Ao ratio cutoff point of 1.04 (p < 0.001). Survival probability was significantly worse in patients with a PA/Ao ratio ≥1.04 (p = 0.005). CONCLUSIONS: The PA/Ao ratio is an easily measurable noninvasive indicator that can predict RVF and 1-year mortality after LVAD implantation.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Heart-Assist DevicesHeart FailureVentricular Dysfunction, RightAdultHumansAdolescentPulmonary ArteryRisk FactorsRetrospective StudiesAorta

Stichwörter der Autor:innen

left ventricular assist devicepulmonary artery to aorta ratioright ventricular failure

Autor:innen und Institutionen

  • Department of Anesthesiology and Perioperative Medicine, Tufts Medical Center, Boston, MA.
  • Department of Anesthesiology, King Saud University College of Medicine, Riyadh, Saudi Arabia.
  • Department of Anesthesiology, Perioperative and Pain Medicine. Brigham and Women's Hospital, Harvard Medical School, Boston, MA. Electronic address: lgonzalezciccarelli@bwh.harvard.edu.
  • Department of Anesthesiology and Perioperative Medicine, University of Massachusetts Memorial Medical Center, Worcester, MA.
  • Department of Cardiac Surgery, Cardiovascular Center, Tufts Medical Center, Boston, MA.

Zitieren

APA

Ferrufino, R. A., Alfadhel, A., Gonzalez-Ciccarelli, L. F., Gebhardt, B., Kawabori, M., Ortoleva, J., Brovman, E., & Cobey, F. (2023). Preoperative Pulmonary Artery-to-Aorta Diameter Ratio as a Predictor of Postoperative Severe Right Ventricular Failure and 1-Year Mortality After Left Ventricular Assist Device Implantation. Journal of Cardiothoracic and Vascular Anesthesia. https://doi.org/10.1053/j.jvca.2023.03.014

Vancouver

Ferrufino RA, Alfadhel A, Gonzalez-Ciccarelli LF, Gebhardt B, Kawabori M, Ortoleva J, et al. Preoperative Pulmonary Artery-to-Aorta Diameter Ratio as a Predictor of Postoperative Severe Right Ventricular Failure and 1-Year Mortality After Left Ventricular Assist Device Implantation. Journal of Cardiothoracic and Vascular Anesthesia. 2023. doi:10.1053/j.jvca.2023.03.014

BibTeX
@article{Ferrufino2023,
  author = {Ferrufino, Renan A and Alfadhel, Abdulaziz and Gonzalez-Ciccarelli, Luis F and Gebhardt, Brian and Kawabori, Masashi and Ortoleva, Jamel and Brovman, Ethan and Cobey, Frederick},
  title = {Preoperative Pulmonary Artery-to-Aorta Diameter Ratio as a Predictor of Postoperative Severe Right Ventricular Failure and 1-Year Mortality After Left Ventricular Assist Device Implantation},
  journal = {Journal of Cardiothoracic and Vascular Anesthesia},
  year = {2023},
  doi = {10.1053/j.jvca.2023.03.014}
}
Kostenlos starten →