EUVIMEDEUVIMED entdecken
Beobachtungsstudie

The Association of Pulmonary Artery to Aorta Diameter Ratio With Postoperative Outcomes Following Left Ventricular Assist Device Implantation

Renan A Ferrufino, Adham Farroukh, Samwel Gitundu, Debora Sepulvida, Amos Alcius, Ethan Brovman, Frederick Cobey, Brian R Gebhardt

Journal of Cardiothoracic and Vascular Anesthesia · 2026

DOI: 10.1053/j.jvca.2026.02.023 ↗

Kurz gefasst

Beobachtungsstudie in der Zeitschrift Journal of Cardiothoracic and Vascular Anesthesia, 2026. Verfasst von Renan A Ferrufino und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Anesthesiology and Perioperative Medicine, Tufts Medical Center, Boston, MA. Electronic address: renanferrufino@hotmail.com. Hauptthemen laut MEDLINE: Heart-Assist Devices, Pulmonary Artery, Aorta, Postoperative Complications. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 29 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVES: The authors aimed to study how the preoperative pulmonary artery to aorta (PA/Ao) diameter ratio in patients undergoing durable left ventricular assist device (LVAD) implantation relates to the duration of inotropic therapy, as well as length of stay (LOS) in the intensive care unit (ICU) and hospital. They hypothesized that the PA/Ao diameter ratio would be associated with longer durations of postoperative inotropic therapy, ICU LOS, and hospital LOS (HLOS). DESIGN: Retrospective observational study between July 2012 and December 2019. SETTING: Single-center study at a quaternary care academic center. PARTICIPANTS: Adults (aged > 18 gt; 18 years) who have undergone LVAD implantation. INTERVENTIONS: LVAD implantation. MEASUREMENTS AND MAIN RESULTS: One hundred fifty-nine patients were evaluated. A larger PA/Ao diameter ratio was associated with increased inotrope duration (odds ratio [OR], 28.80; 95% confidence interval [CI], 10.56-78.55; p < 0.0001), ICU LOS (OR, 2.86; 95% CI, 1.29-6.33; p < 0.03), and HLOS (OR, 2.96; 95% CI, 1.21-7.26; p = 0.02). The PA/Ao diameter ratio showed significant moderate positive correlations with clinical outcomes. Specifically, each 0.04-, 0.08-, and 0.06-unit increase in the ratio was associated with 1 additional day of inotropic therapy, a 1-day increase in ICU LOS, and a 1-day increase in HLOS, respectively. CONCLUSIONS: The findings support the hypothesis that larger PA/Ao diameter ratios are associated with increased durations of postoperative inotropic support, ICU LOS, and HLOS. The PA/Ao diameter ratio may be a valuable risk assessment tool in patients undergoing LVAD implantation.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Heart-Assist DevicesPulmonary ArteryAortaPostoperative ComplicationsHeart FailureHumansRetrospective StudiesFemaleMaleMiddle AgedLength of StayTreatment OutcomeAdult

Autor:innen und Institutionen

  • Department of Anesthesiology and Perioperative Medicine, Tufts Medical Center, Boston, MA. Electronic address: renanferrufino@hotmail.com.
  • Department of Anesthesiology and Perioperative Medicine, University of Massachusetts Memorial Medical Center, Worcester, MA. Electronic address: adhamfarroukh@gmail.com.
  • Department of Anesthesiology and Perioperative Medicine, Tufts Medical Center, Boston, MA. Electronic address: gitundusamwel@gmail.com.
  • Department of Anesthesiology and Perioperative Medicine, Tufts Medical Center, Boston, MA. Electronic address: deborasepulvida@gmail.com.
  • Department of Anesthesiology and Perioperative Medicine, Tufts Medical Center, Boston, MA. Electronic address: amosal12@gmail.com.
  • Department of Anesthesiology and Perioperative Medicine, Tufts Medical Center, Boston, MA. Electronic address: Ethan.Brovman@tuftsmedicine.org.

Zitieren

APA

Ferrufino, R. A., Farroukh, A., Gitundu, S., Sepulvida, D., Alcius, A., Brovman, E., Cobey, F., & Gebhardt, B. R. (2026). The Association of Pulmonary Artery to Aorta Diameter Ratio With Postoperative Outcomes Following Left Ventricular Assist Device Implantation. Journal of Cardiothoracic and Vascular Anesthesia. https://doi.org/10.1053/j.jvca.2026.02.023

Vancouver

Ferrufino RA, Farroukh A, Gitundu S, Sepulvida D, Alcius A, Brovman E, et al. The Association of Pulmonary Artery to Aorta Diameter Ratio With Postoperative Outcomes Following Left Ventricular Assist Device Implantation. Journal of Cardiothoracic and Vascular Anesthesia. 2026. doi:10.1053/j.jvca.2026.02.023

BibTeX
@article{Ferrufino2026,
  author = {Ferrufino, Renan A and Farroukh, Adham and Gitundu, Samwel and Sepulvida, Debora and Alcius, Amos and Brovman, Ethan and Cobey, Frederick and Gebhardt, Brian R},
  title = {The Association of Pulmonary Artery to Aorta Diameter Ratio With Postoperative Outcomes Following Left Ventricular Assist Device Implantation},
  journal = {Journal of Cardiothoracic and Vascular Anesthesia},
  year = {2026},
  doi = {10.1053/j.jvca.2026.02.023}
}
Kostenlos starten →