Accuracy of acetabular component alignment with surgical guidance systems during hip arthroplasty
SICOT-J · 2023 · 9 · 12
DOI: 10.1051/sicotj/2023010 ↗Kurz gefasst
Fachartikel in der Zeitschrift SICOT-J, online erschienen am 05.05.2023. Verfasst von Joshua Xu und 3 weiteren Autor:innen. Beteiligte Einrichtung: University of Sydney, Sydney, New South Wales, Australia - Department of Orthopaedic and Trauma Surgery, Royal North Shore Hospital, St. Leonards, Ne…. Die Arbeit wurde bisher 13-mal zitiert (Crossref) und nennt 17 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background
Navigation in total hip arthroplasty has been shown to improve acetabular positioning and can decrease the incidence of mal-positioned acetabular components. This study aimed to assess two surgical guidance systems by comparing intra-operative measurements of acetabular component inclination and anteversion with a post-operative CT scan.
Methods
We prospectively collected intra-operative navigation data from 102 hips receiving conventional THA or hip resurfacing arthroplasty through either a direct anterior or posterior approach. Two guidance systems were used simultaneously: an inertial navigation system (INS) and an optical navigation system (ONS). Acetabular component anteversion and inclination were measured on a post-operative CT.
Results
The average age of the patients was 64 years (range: 24–92) and the average BMI was 27 kg/m 2 (range 19–38). 52% had hip surgery through an anterior approach. 98% of the INS measurements and 88% of the ONS measurements were within 10° of the CT measurements. The mean (and standard deviation) of the absolute difference between the postoperative CT and the intra-operative measurements for inclination and anteversion were 3.0° (2.8) and 4.5° (3.2) respectively for the ONS, along with 2.1° (2.3) and 2.4° (2.1) respectively for the INS. There was a significantly lower mean absolute difference to CT for the INS when compared to ONS in both anteversions ( p < 0.001) and inclination ( p = 0.02).
Conclusions
We found that both inertial and optical navigation systems allowed for adequate acetabular positioning as measured on postoperative CT, and thus provide reliable intraoperative feedback for optimal acetabular component placement. Level of Evidence: Therapeutic Level II.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- University of Sydney, Sydney, New South Wales, Australia - Department of Orthopaedic and Trauma Surgery, Royal North Shore Hospital, St. Leonards, New South Wales, Australia - Tom Reeve Academic Clinic, Ground Floor Kol…
- Department of Orthopaedic and Trauma Surgery, Royal North Shore Hospital, St. Leonards, New South Wales, Australia.
- University of Sydney, Sydney, New South Wales, Australia.
- University of Sydney, Sydney, New South Wales, Australia - Department of Orthopaedic and Trauma Surgery, Royal North Shore Hospital, St. Leonards, New South Wales, Australia.
ORCID-Profile: Joshua Xu
Zitieren
APA
Xu, J., Veltman, E. S., Chai, Y., & Walter, W. L. (2023). Accuracy of acetabular component alignment with surgical guidance systems during hip arthroplasty. SICOT-J, 9, 12. https://doi.org/10.1051/sicotj/2023010
Vancouver
Xu J, Veltman ES, Chai Y, Walter WL. Accuracy of acetabular component alignment with surgical guidance systems during hip arthroplasty. SICOT-J. 2023;9:12. doi:10.1051/sicotj/2023010
BibTeX
@article{Xu2023,
author = {Xu, Joshua and Veltman, Ewout S and Chai, Yuan and Walter, William L},
title = {Accuracy of acetabular component alignment with surgical guidance systems during hip arthroplasty},
journal = {SICOT-J},
year = {2023},
volume = {9},
pages = {12},
doi = {10.1051/sicotj/2023010}
}
EUVIMED