Mixed Reality Guidance Improves Acetabular Component Positioning Accuracy During Simulated Total Hip Arthroplasty: A Prospective Pilot Study
Prosthesis · 21.07.2026 · 8 (7) · 78
DOI: 10.3390/prosthesis8070078 ↗Kurz gefasst
Fachartikel in der Zeitschrift Prosthesis, online erschienen am 21.07.2026. Verfasst von Javier Hernández-Balada und 3 weiteren Autor:innen. Die Arbeit nennt 19 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: FISABIO.
Abstract (Originalsprache)
Background
Accurate acetabular component positioning is critical to the success of total hip arthroplasty (THA). Mixed reality (MR)-based simulation offers a novel approach to surgical training by providing real-time feedback within immersive learning environments. This study evaluated the impact of an MR-based simulation on technical performance, as well as its usability and user experience.
Methods
A prospective pre–post pilot educational study was conducted in a controlled simulation laboratory using a physical anatomical model. Forty-six final-year medical students with no prior experience in MR technology participated. Participants performed acetabular component positioning tasks before and after MR-assisted training. Technical accuracy was assessed by measuring deviations in inclination and anteversion. Usability, workload, presence, and cybersickness were evaluated using validated questionnaires.
Results
MR-assisted training significantly improved technical accuracy. Median absolute deviation in inclination decreased from 1.0° (interquartile range [IQR], 1.0–3.5) to 0.5° (IQR, 0.0–2.0) (p = 0.0008, r = 0.56), while anteversion deviation decreased from 4.5° (IQR, 2.0–7.0) to 2.0° (IQR, 1.0–4.0) (p < 0.0001, r = 0.66). User experience scores ranked the application among top-performing systems in benchmark comparisons. Participants reported high levels of presence and usability, low workload (all NASA-TLX domains
Förderung
- FISABIO
Zitieren
APA
Hernández-Balada, J., Mifsut, D., Juan, M., & Valverde-Navarro, A. A. (2026). Mixed Reality Guidance Improves Acetabular Component Positioning Accuracy During Simulated Total Hip Arthroplasty: A Prospective Pilot Study. Prosthesis, 8(7), 78. https://doi.org/10.3390/prosthesis8070078
Vancouver
Hernández-Balada J, Mifsut D, Juan M, Valverde-Navarro AA. Mixed Reality Guidance Improves Acetabular Component Positioning Accuracy During Simulated Total Hip Arthroplasty: A Prospective Pilot Study. Prosthesis. 2026;8(7):78. doi:10.3390/prosthesis8070078
BibTeX
@article{HernndezBalada2026,
author = {Hernández-Balada, Javier and Mifsut, Damian and Juan, M.-Carmen and Valverde-Navarro, Alfonso Amador},
title = {Mixed Reality Guidance Improves Acetabular Component Positioning Accuracy During Simulated Total Hip Arthroplasty: A Prospective Pilot Study},
journal = {Prosthesis},
year = {2026},
volume = {8},
number = {7},
pages = {78},
doi = {10.3390/prosthesis8070078}
}