Vergleichsstudie in der Zeitschrift The Analyst, 2025. Verfasst von Arhama T A Ansari und 6 weiteren Autor:innen. Beteiligte Einrichtung: Environmental Science and Engineering Department, Indian Institute of Technology, Bombay, Mumbai, 400076, India. mitras@iitb.ac.in. Hauptthemen laut MEDLINE: Water Pollutants, Chemical, Tandem Mass Spectrometry, Anti-Bacterial Agents, Wastewater. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 55 Literaturangaben. Gefördert von: Natural Environment Research Council, Department of Biotechnology, Ministry of Science and Technology.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Direct comparison of LC-QqQ-MS and LC-Orbitrap-HRMS reveals complementary strengths for environmental antibiotic monitoring in CETP-impacted creek water.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Water Pollutants, ChemicalTandem Mass SpectrometryAnti-Bacterial AgentsWastewaterLimit of DetectionRiversChromatography, Liquid

Substanzen

Water Pollutants, ChemicalAnti-Bacterial AgentsWastewater

Autor:innen und Institutionen

  • Environmental Science and Engineering Department, Indian Institute of Technology, Bombay, Mumbai, 400076, India. mitras@iitb.ac.in.
  • Department of Biosciences and Bioengineering, Indian Institute of Technology, Bombay, Mumbai, India.
  • School of Computing, Engineering & Physical Sciences, University of the West of Scotland, Paisley, UK.
  • Department of Civil and Environmental Engineering, University of Strathclyde, Glasgow, UK.
  • Glasgow School for Business and Society, Glasgow Caledonian University, Glasgow, UK.

Förderung

  • Natural Environment Research Council
  • Department of Biotechnology, Ministry of Science and Technology

Zitieren

APA

Ansari, A. T. A., Ransingh, A., Mukherji, S., Hursthouse, A., Henriquez, F. L., Connolly, J., & Mukherji, S. (2025). Comparative performance evaluation of triple quadrupole tandem mass spectrometry and orbitrap high-resolution mass spectrometry for analysis of antibiotics in creek water impacted by CETP discharge. The Analyst. https://doi.org/10.1039/d5an00482a

Vancouver

Ansari ATA, Ransingh A, Mukherji S, Hursthouse A, Henriquez FL, Connolly J, et al. Comparative performance evaluation of triple quadrupole tandem mass spectrometry and orbitrap high-resolution mass spectrometry for analysis of antibiotics in creek water impacted by CETP discharge. The Analyst. 2025. doi:10.1039/d5an00482a

BibTeX
@article{Ansari2025,
  author = {Ansari, Arhama T A and Ransingh, Ayush and Mukherji, Soumyo and Hursthouse, Andrew and Henriquez, Fiona L and Connolly, John and Mukherji, Suparna},