EUVIMEDEUVIMED entdecken
Crossref

Early detection of hypo/hyperglycemia using a microneedle electrode array-based biosensor for glucose ultrasensitive monitoring in interstitial fluid

Samar H Tawakey, Mohammad Mansour iD, Ahmed Soltan, Alyaa I Salim iD

Lab on a Chip · 2024 · 24 (16) · 3958-3972

DOI: 10.1039/d4lc00365a ↗

Kurz gefasst

Fachartikel in der Zeitschrift Lab on a Chip, 2024. Verfasst von Samar H Tawakey und 3 weiteren Autor:innen. Beteiligte Einrichtung: Nanoelectronics Integrated Systems Center (NISC), Nile University, 26th of July Corridor, Sheikh Zayed City, 12588, Giza, Egypt. Hauptthemen laut MEDLINE: Biosensing Techniques, Extracellular Fluid, Needles, Glucose. Die Arbeit wurde bisher 35-mal zitiert (Crossref) und nennt 61 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

A fully integrated, high-precision, wearable electrochemical microneedle sensing device that works with a customized smartphone application to wirelessly and in real-time monitor glucose of hypo/hyperglycemia in human ISF.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Biosensing TechniquesExtracellular FluidNeedlesGlucoseHumansElectrodesHypoglycemiaLimit of DetectionPolymethyl Methacrylate

Substanzen

GlucosePolymethyl Methacrylate

Autor:innen und Institutionen

  • Nanoelectronics Integrated Systems Center (NISC), Nile University, 26th of July Corridor, Sheikh Zayed City, 12588, Giza, Egypt.
  • Chemistry Department, Faculty of Science, Tanta University, Tanta 31527, Egypt.
  • School of Biotechnology, Nile University, 26th of July Corridor, Sheikh Zayed City, 12588, Giza, Egypt. asalim@nu.edu.eg.

ORCID-Profile: Mohammad Mansour, Alyaa I Salim

Zitieren

APA

Tawakey, S. H., Mansour, M., Soltan, A., & Salim, A. I. (2024). Early detection of hypo/hyperglycemia using a microneedle electrode array-based biosensor for glucose ultrasensitive monitoring in interstitial fluid. Lab on a Chip, 24(16), 3958-3972. https://doi.org/10.1039/d4lc00365a

Vancouver

Tawakey SH, Mansour M, Soltan A, Salim AI. Early detection of hypo/hyperglycemia using a microneedle electrode array-based biosensor for glucose ultrasensitive monitoring in interstitial fluid. Lab on a Chip. 2024;24(16):3958-3972. doi:10.1039/d4lc00365a

BibTeX
@article{Tawakey2024,
  author = {Tawakey, Samar H and Mansour, Mohammad and Soltan, Ahmed and Salim, Alyaa I},
  title = {Early detection of hypo/hyperglycemia using a microneedle electrode array-based biosensor for glucose ultrasensitive monitoring in interstitial fluid},
  journal = {Lab on a Chip},
  year = {2024},
  volume = {24},
  number = {16},
  pages = {3958--3972},
  doi = {10.1039/d4lc00365a}
}
Kostenlos starten →