EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Regarding Emitter Positioning for Nanoflow Electrospray Ionization with a High-Capacity Inlet Capillary

Noah M Lancaster iD, Scott T Quarmby iD, Katherine A Overmyer iD, Joshua J Coon iD

Journal of the American Society for Mass Spectrometry · 2026

DOI: 10.1021/jasms.5c00441 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of the American Society for Mass Spectrometry, 2026. Verfasst von Noah M Lancaster und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry, University of Wisconsin-Madison, Madison, Wisconsin 53706, United States. Hauptthemen laut MEDLINE: Spectrometry, Mass, Electrospray Ionization, Proteomics, Nanotechnology. Die Arbeit nennt 39 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NIGMS NIH HHS, National Institute of General Medical Sciences.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Nanoflow electrospray ionization is commonly used for proteomics due to its high sensitivity. Signal intensity, however, is dependent on optimal emitter positioning relative to the mass spectrometer inlet. Here, we characterize the effect of varied emitter positions on peptide signal intensity in all three dimensions using emitters and flows consistent with standard proteomic analyses. We observe improved signal robustness to x/y variations at increasing z distances and demonstrate that positioning within 1 to 2 mm of the optimal location will maintain consistent signal. Signal intensity behavior is consistent across the m/z range, suggesting emitter positions do not need to be fine-tuned for different analytes for proteomics analyses. These results provide insight for proteomics researchers using nanoflow LC-MS/MS.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Spectrometry, Mass, Electrospray IonizationProteomicsNanotechnologyTandem Mass SpectrometryLiquid Chromatography-Mass SpectrometryPeptidesEquipment Design

Stichwörter der Autor:innen

emitter positioninginlet capillaryion plume characterizationnanoflow electrospray ionizationproteomics

Substanzen

Peptides

Autor:innen und Institutionen

  • Department of Chemistry, University of Wisconsin-Madison, Madison, Wisconsin 53706, United States.
  • Department of Biomolecular Chemistry, University of Wisconsin-Madison, Madison, Wisconsin 53706, United States.
  • Morgridge Institute for Research, Madison, Wisconsin 53715, United States.

ORCID-Profile: Noah M Lancaster, Scott T Quarmby, Katherine A Overmyer, Joshua J Coon

Förderung

  • NIGMS NIH HHS
  • National Institute of General Medical Sciences

Zitieren

APA

Lancaster, N. M., Quarmby, S. T., Overmyer, K. A., & Coon, J. J. (2026). Regarding Emitter Positioning for Nanoflow Electrospray Ionization with a High-Capacity Inlet Capillary. Journal of the American Society for Mass Spectrometry. https://doi.org/10.1021/jasms.5c00441

Vancouver

Lancaster NM, Quarmby ST, Overmyer KA, Coon JJ. Regarding Emitter Positioning for Nanoflow Electrospray Ionization with a High-Capacity Inlet Capillary. Journal of the American Society for Mass Spectrometry. 2026. doi:10.1021/jasms.5c00441

BibTeX
@article{Lancaster2026,
  author = {Lancaster, Noah M and Quarmby, Scott T and Overmyer, Katherine A and Coon, Joshua J},
  title = {Regarding Emitter Positioning for Nanoflow Electrospray Ionization with a High-Capacity Inlet Capillary},
  journal = {Journal of the American Society for Mass Spectrometry},
  year = {2026},
  doi = {10.1021/jasms.5c00441}
}
Kostenlos starten →