Regarding Emitter Positioning for Nanoflow Electrospray Ionization with a High-Capacity Inlet Capillary
Journal of the American Society for Mass Spectrometry · 2026
DOI: 10.1021/jasms.5c00441 ↗At a glance
Journal article in Journal of the American Society for Mass Spectrometry, 2026. Written by Noah M Lancaster and 3 co-authors. Institution: Department of Chemistry, University of Wisconsin-Madison, Madison, Wisconsin 53706, United States. Major MEDLINE topics: Spectrometry, Mass, Electrospray Ionization, Proteomics, Nanotechnology. 39 references. The full text is freely available (open access, CC BY 4.0). Funded by: NIGMS NIH HHS, National Institute of General Medical Sciences.
Abstract (original language)
Nanoflow electrospray ionization is commonly used for proteomics due to its high sensitivity. Signal intensity, however, is dependent on optimal emitter positioning relative to the mass spectrometer inlet. Here, we characterize the effect of varied emitter positions on peptide signal intensity in all three dimensions using emitters and flows consistent with standard proteomic analyses. We observe improved signal robustness to x/y variations at increasing z distances and demonstrate that positioning within 1 to 2 mm of the optimal location will maintain consistent signal. Signal intensity behavior is consistent across the m/z range, suggesting emitter positions do not need to be fine-tuned for different analytes for proteomics analyses. These results provide insight for proteomics researchers using nanoflow LC-MS/MS.
Subjects
MeSH terms (MEDLINE)
Author keywords
Substances
Authors and institutions
- Department of Chemistry, University of Wisconsin-Madison, Madison, Wisconsin 53706, United States.
- Department of Biomolecular Chemistry, University of Wisconsin-Madison, Madison, Wisconsin 53706, United States.
- Morgridge Institute for Research, Madison, Wisconsin 53715, United States.
ORCID profiles: Noah M Lancaster, Scott T Quarmby, Katherine A Overmyer, Joshua J Coon
Funding
- NIGMS NIH HHS
- National Institute of General Medical Sciences
Cite
APA
Lancaster, N. M., Quarmby, S. T., Overmyer, K. A., & Coon, J. J. (2026). Regarding Emitter Positioning for Nanoflow Electrospray Ionization with a High-Capacity Inlet Capillary. Journal of the American Society for Mass Spectrometry. https://doi.org/10.1021/jasms.5c00441
Vancouver
Lancaster NM, Quarmby ST, Overmyer KA, Coon JJ. Regarding Emitter Positioning for Nanoflow Electrospray Ionization with a High-Capacity Inlet Capillary. Journal of the American Society for Mass Spectrometry. 2026. doi:10.1021/jasms.5c00441
BibTeX
@article{Lancaster2026,
author = {Lancaster, Noah M and Quarmby, Scott T and Overmyer, Katherine A and Coon, Joshua J},
title = {Regarding Emitter Positioning for Nanoflow Electrospray Ionization with a High-Capacity Inlet Capillary},
journal = {Journal of the American Society for Mass Spectrometry},
year = {2026},
doi = {10.1021/jasms.5c00441}
}
EUVIMED