Journal article in Journal of the American Society for Mass Spectrometry, 2026. Written by Andrew K Swansiger and 7 co-authors. Institution: Department of Chemistry and Biochemistry, University of Oregon, 1253 University of Oregon, Eugene, Oregon 97403-1253, United States. Major MEDLINE topics: Proteins, Image Processing, Computer-Assisted, Mass Spectrometry. Cited 2 times so far (Crossref); 29 references. Funded by: Division of Chemistry, Division of Engineering Education and Centers, Common Fund.

AbstraktSubjectsBibliografické údajeCiteRelated studies

Abstract (original language)

Histological and immunofluorescence imaging techniques are widely used for studying protein localization in biological tissues, from the identification of disease to the development of drugs with greater target specificity and lower toxicity. However, the complexity of such samples often requires the use of chemical labels and targeted analysis, thereby limiting proteome coverage. In contrast, mass spectrometry imaging (MSI) enables label-free, highly multiplexed analysis of tissue proteomes with cellular spatial resolution. The complexity of protein mixtures analyzed in MSI often leads to mass spectra at each pixel in the image with extensive signal overlap and a pronounced, curved baseline, which complicates data analysis and interpretation. Here, we introduce a parallelized Gábor-transform-based batch deconvolution workflow ("iFAMS Imager") that resolves strongly overlapping protein signals in MSI and offers flexible options for baseline correction. Together, these advantages facilitate the removal of interferent signals strongly overlapped in m/z with those of the target analyte, resulting in high-fidelity images. Use of this open-source, publicly available software is demonstrated for imaging of common proteins in rat brain tissue.

Subjects

MeSH terms (MEDLINE)

ProteinsImage Processing, Computer-AssistedMass SpectrometryAnimalsRatsBrainBrain ChemistrySoftwareProteomics

Substances

Proteins

Authors and institutions

  • Department of Chemistry and Biochemistry, University of Oregon, 1253 University of Oregon, Eugene, Oregon 97403-1253, United States.
  • James Tarpo Jr. and Margaret Tarpo Department of Chemistry, Purdue University, West Lafayette, Indiana 47907, United States.
  • Materials Science Institute, University of Oregon, 1252 University of Oregon, Eugene, Oregon 97403-1252, United States.

ORCID profiles: Andrew K Swansiger, Manxi Yang, Mushfeqa Iqfath, Julia Laskin, James S Prell

Funding

  • Division of Chemistry
  • Division of Engineering Education and Centers
  • Common Fund

Cite

APA

Swansiger, A. K., Miller, L., Meldrum, K. L., Yang, M., Iqfath, M., Hu, H., Laskin, J., & Prell, J. S. (2026). iFAMS Imager: Analyte Deconvolution and Baseline Correction for Mass Spectrometry Imaging of Proteins. Journal of the American Society for Mass Spectrometry. https://doi.org/10.1021/jasms.5c00317

Vancouver

Swansiger AK, Miller L, Meldrum KL, Yang M, Iqfath M, Hu H, et al. iFAMS Imager: Analyte Deconvolution and Baseline Correction for Mass Spectrometry Imaging of Proteins. Journal of the American Society for Mass Spectrometry. 2026. doi:10.1021/jasms.5c00317

BibTeX
@article{Swansiger2026,
  author = {Swansiger, Andrew K and Miller, Lily and Meldrum, Kayd L and Yang, Manxi and Iqfath, Mushfeqa and Hu, Hang and Laskin, Julia and Prell, James S},
  title = {iFAMS Imager: Analyte Deconvolution and Baseline Correction for Mass Spectrometry Imaging of Proteins},
  journal = {Journal of the American Society for Mass Spectrometry},
  year = {2026},
  doi = {10.1021/jasms.5c00317}
}
Start for free →