EUVIMEDEUVIMED entdecken
Crossref

Using long columns to quantify over 9200 unique protein groups from brain tissue in a single injection on an Orbitrap Exploris 480 mass spectrometer

Xianyin Lai, Guihong Qi

Journal of Proteomics · 2024

DOI: 10.1016/j.jprot.2024.105285 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Proteomics, 2024. Verfasst von Xianyin Lai und 1 weiteren Autor:innen. Beteiligte Einrichtung: Biotechnology Discovery Research, Lilly Research Laboratories, Eli Lilly and Company, Indianapolis, IN, USA. Electronic address: Xianyin.lai@Lilly.co…. Hauptthemen laut MEDLINE: Proteomics, Brain Chemistry. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 31 Literaturangaben. Gefördert von: Eli Lilly and Company.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The most exciting advancement in LC-MS/MS-based bottom-up proteomics has centered around enhancing mass spectrometers. Among these, the latest and most advanced mass spectrometer for bottom-up proteomics is the Orbitrap Astral that has the highest scan rate to accelerate throughput and the highest sensitivity to handle a very small amount of peptide samples and to achieve deeper proteomics. However, its affordability remains a challenge for most laboratories. While significant strides have been made in improving mass spectrometry, advancing liquid chromatography (LC) to achieve deeper proteomics has not achieved significant successes since the innovation of Multidimensional Protein Identification Technology (MudPIT) in 2001. To achieve deeper proteomics in a less labor-intensive and more reproducible approach while using a more cost-effective mass spectrometer, such as the Orbitrap Exploris 480, we evaluated trap columns as long as 40 cm and analytical column as long as 600 cm besides sample loading amount, gradient time, and analytical column particle size to enable a fractionation-free method for a single injection to obtain deeper proteomics. The length of trap and analytic columns is the key factor. Using a 30 cm trap column and 250 cm analytical column with other optimized LC conditions, we quantified over 9200 unique protein groups from brain tissue in a single injection using a 24-h gradient on an Orbitrap Exploris 480 mass spectrometer.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ProteomicsBrain ChemistryAnimalsChromatography, LiquidBrainMass SpectrometryTandem Mass SpectrometryMiceProteins

Stichwörter der Autor:innen

Deep proteomicsFractionation-freeLong columnOrbitrap Exploris 480Single injection

Substanzen

Proteins

Autor:innen und Institutionen

  • Biotechnology Discovery Research, Lilly Research Laboratories, Eli Lilly and Company, Indianapolis, IN, USA. Electronic address: Xianyin.lai@Lilly.com.
  • Biotechnology Discovery Research, Lilly Research Laboratories, Eli Lilly and Company, Indianapolis, IN, USA.

Förderung

  • Eli Lilly and Company

Zitieren

APA

Lai, X., & Qi, G. (2024). Using long columns to quantify over 9200 unique protein groups from brain tissue in a single injection on an Orbitrap Exploris 480 mass spectrometer. Journal of Proteomics. https://doi.org/10.1016/j.jprot.2024.105285

Vancouver

Lai X, Qi G. Using long columns to quantify over 9200 unique protein groups from brain tissue in a single injection on an Orbitrap Exploris 480 mass spectrometer. Journal of Proteomics. 2024. doi:10.1016/j.jprot.2024.105285

BibTeX
@article{Lai2024,
  author = {Lai, Xianyin and Qi, Guihong},
  title = {Using long columns to quantify over 9200 unique protein groups from brain tissue in a single injection on an Orbitrap Exploris 480 mass spectrometer},
  journal = {Journal of Proteomics},
  year = {2024},
  doi = {10.1016/j.jprot.2024.105285}
}
Kostenlos starten →