EUVIMEDSkopri EUVIMED
Open access · CC BY 4.0

IscS Kinetics in Native Mass Spectrometry Buffers Reveal Key Physiochemical Properties that Influence Enzyme Activity

Shelby D Oney-Hawthorne, David P Barondeau iD, David H Russell iD

Journal of the American Society for Mass Spectrometry · 2026

DOI: 10.1021/jasms.5c00280 ↗

At a glance

Journal article in Journal of the American Society for Mass Spectrometry, 2026. Written by Shelby D Oney-Hawthorne and 2 co-authors. Institution: Department of Chemistry, Texas A&M University, College Station, Texas 77842, United States. Major MEDLINE topics: Mass Spectrometry, Carbon-Sulfur Lyases. 76 references. The full text is freely available (open access, CC BY 4.0). Funded by: NIGMS NIH HHS, Welch Foundation, National Institute of General Medical Sciences.

AstrattSubjectsDettalji biblijografiċiCiteRelated studies

Abstract (original language)

Investigations of protein function and interactions with native mass spectrometry (MS) have yielded significant insights into protein dynamics, transient reaction intermediates, and pharmacokinetic targets. The pursuit of these studies and their outcomes depend on the preparation of protein samples in a manner able to support native conformation, active site chemistry, and protein-ligand interactions. Although ammonium acetate is a commonly utilized volatile buffer in MS-based analyses, the gap in buffer capacity near physiological pH calls into question whether this or other volatile buffer solutions are able to facilitate native conformation and protein-ligand interactions in the gas phase. We report enzymatic activity of the cysteine desulfurase IscS in four volatile buffer solutions comparable to that observed in traditionally utilized buffers such as Tris and HEPES, which is heavily influenced by buffer contributions to protein conformation and stability. We present a dual analysis of MS charge state and enzyme kinetics in the context of protein and solution physical properties, providing a chemical justification for the positive and negative effects of specific buffers. Ultimately, these results demonstrate how native MS technology can be used to identify protein conformational and dynamic interactions modulated by buffer systems to guide mechanistic studies.

Subjects

MeSH terms (MEDLINE)

Mass SpectrometryCarbon-Sulfur LyasesBuffersKineticsProtein ConformationAcetates

Author keywords

buffer capacityenzyme kineticsnative protein mass spectrometryvolatile buffers

Substances

BuffersCarbon-Sulfur LyasesAcetates

Authors and institutions

  • Department of Chemistry, Texas A&M University, College Station, Texas 77842, United States.

ORCID profiles: David P Barondeau, David H Russell

Funding

  • NIGMS NIH HHS
  • Welch Foundation
  • National Institute of General Medical Sciences

Cite

APA

Oney-Hawthorne, S. D., Barondeau, D. P., & Russell, D. H. (2026). IscS Kinetics in Native Mass Spectrometry Buffers Reveal Key Physiochemical Properties that Influence Enzyme Activity. Journal of the American Society for Mass Spectrometry. https://doi.org/10.1021/jasms.5c00280

Vancouver

Oney-Hawthorne SD, Barondeau DP, Russell DH. IscS Kinetics in Native Mass Spectrometry Buffers Reveal Key Physiochemical Properties that Influence Enzyme Activity. Journal of the American Society for Mass Spectrometry. 2026. doi:10.1021/jasms.5c00280

BibTeX
@article{OneyHawthorne2026,
  author = {Oney-Hawthorne, Shelby D and Barondeau, David P and Russell, David H},
  title = {IscS Kinetics in Native Mass Spectrometry Buffers Reveal Key Physiochemical Properties that Influence Enzyme Activity},
  journal = {Journal of the American Society for Mass Spectrometry},
  year = {2026},
  doi = {10.1021/jasms.5c00280}
}
Start for free →