Buffer 4‐Ethylmorpholinium/Acetate: Exploring a New Alternative Buffer for Native Mass Spectrometry
Rapid Communications in Mass Spectrometry · 2025
DOI: 10.1002/rcm.10048 ↗Kurz gefasst
Fachartikel in der Zeitschrift Rapid Communications in Mass Spectrometry, 2025. Verfasst von Darya Hadavi und 8 weiteren Autor:innen. Beteiligte Einrichtung: Maastricht Multi Modal Molecular Imaging (M4i) Institute, Division of Imaging Mass Spectrometry (IMS), Maastricht University, Maastricht, The Netherl…. Hauptthemen laut MEDLINE: Spectrometry, Mass, Electrospray Ionization, Buffers, Morpholines. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 51 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Dutch Province of Limburg, DARTBAC, Dutch Research Council.
Abstract (Originalsprache)
Rationale
To perform native mass spectrometry (MS) studies, there are a limited number of volatile and electrospray ionization (ESI)‐MS compatible solutions, such as ammonium bicarbonate and ammonium acetate (AA). These solutions could induce the unfolding of proteins due to the formation of CO 2 bubbles or induced acidification during ESI. Hence, it was important to introduce a buffer suitable to preserve the native form of proteins while simulating physiological conditions.
Methods
The 4‐ethylmorpholinium/acetate (4EM/A) buffer was compared to AA for the analysis of proteins and protein complexes with mass ranges from 5 to 103 kDa and isoelectric points (pI) between 3 and 11. The evaluations were conducted by comparing the native‐MS profiles, CCS values, arrival time distributions (ATDs), and proteins bioactivities. The human cardiac troponin complex (cTn complex) and its subunit cardiac troponin T (cTnT) were analyzed as proof of the applicability of this buffer for challenging proteins and protein complexes.
Results
4EM/A led to lower charge states compared to AA, supporting the likelihood of preserving protein folding during nano‐ESI and in a high vacuum environment of MS. Ion mobility measurements revealed that proteins in 4EM/A exhibit a lower degree of conformational variation compared to AA, suggesting enhanced conformational stability and potential retention of natural‐like compactness. Additionally, testing the impact of 4EM/A on bioactivity, lysozyme showed increased biological activity in 4EM/A relative to AA, highlighting the buffer's potential for real‐time assessment of protein interaction kinetics and bioactivity. The 4EM/A buffer enabled native‐MS analysis of cTnT for the first time.
Conclusion
We introduced 4EM/A, with pK a of 7.72/4.76, as a promising buffer for native‐MS studies to maintain protein and protein complex bioactivity and conformational integrity.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Maastricht Multi Modal Molecular Imaging (M4i) Institute, Division of Imaging Mass Spectrometry (IMS), Maastricht University, Maastricht, The Netherlands.
- MERLN Institute for Technology-Inspired Regenerative Medicine, Department of Cell Biology-Inspired Tissue Engineering (cBITE), Maastricht University, Maastricht, The Netherlands.
ORCID-Profile: Yuandi Zhao
Förderung
- Dutch Province of Limburg
- DARTBAC
- Dutch Research Council
Zitieren
APA
Hadavi, D., Ng, C. Y., Zhao, Y., Mathew, A., Anthony, I. G. M., Cillero-Pastor, B., Cuypers, E., Siegel, T. P., & Honing, M. (2025). Buffer 4‐Ethylmorpholinium/Acetate: Exploring a New Alternative Buffer for Native Mass Spectrometry. Rapid Communications in Mass Spectrometry. https://doi.org/10.1002/rcm.10048
Vancouver
Hadavi D, Ng CY, Zhao Y, Mathew A, Anthony IGM, Cillero-Pastor B, et al. Buffer 4‐Ethylmorpholinium/Acetate: Exploring a New Alternative Buffer for Native Mass Spectrometry. Rapid Communications in Mass Spectrometry. 2025. doi:10.1002/rcm.10048
BibTeX
@article{Hadavi2025,
author = {Hadavi, Darya and Ng, Che Yee and Zhao, Yuandi and Mathew, Anjusha and Anthony, Ian G M and Cillero-Pastor, Berta and Cuypers, Eva and Siegel, Tiffany Porta and Honing, Maarten},
title = {Buffer 4‐Ethylmorpholinium/Acetate: Exploring a New Alternative Buffer for Native Mass Spectrometry},
journal = {Rapid Communications in Mass Spectrometry},
year = {2025},
doi = {10.1002/rcm.10048}
}
EUVIMED