EUVIMEDOpdag EUVIMED
Crossref

Integrating Electrostatic Adsorption-Laser Desorption/Ionization-MS with a Derivative Full-Spectrum Internal Standard Approach for Acylcarnitine Quantification in Clinical Samples

Shuo Cao, Xinrong Jiang, Xiaoming Chen, Xuetong Qu, Jianmin Wu iD

Journal of the American Society for Mass Spectrometry · 2025

DOI: 10.1021/jasms.5c00136 ↗

At a glance

Journal article in Journal of the American Society for Mass Spectrometry, 2025. Written by Shuo Cao and 4 co-authors. Institution: Institution of Analytical Chemistry, Department of Chemistry, Zhejiang University, Hangzhou, Zhejiang 310058, China. Major MEDLINE topics: Carnitine, Spectrometry, Mass, Matrix-Assisted Laser Desorption-Ionization. Cited 2 times so far (Crossref); 43 references. Funded by: National Natural Science Foundation of China.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Acylcarnitines (ACs), essential intermediates in fatty acid β-oxidation, are increasingly recognized as biomarkers for inborn errors of metabolism (IEM), insulin resistance, heart failure, and neurodegenerative diseases. However, conventional liquid chromatography-mass spectrometry (LC-MS) and flow injection-mass spectrometry (FI-MS) methods are hindered by complex sample preparation, limited throughput, and matrix interferences. Meanwhile, matrix-assisted laser desorption/ionization-MS (MALDI-MS) suffers from low-mass background noise and poor reproducibility. Here, we present a dual-innovation mass spectrometry platform combining a substrate composed of sulfonic acid-gold nanoparticle-decorated silicon nanowires (Sulfo-Au-SiNWs) for electrostatic adsorption-laser desorption/ionization (EALDI) and a full-spectrum internal standard (FS IS) strategy based on d6-ethanol derivatization. The optimized Sulfo-Au-SiNWs offer uniform crystallinity, in situ electrostatic enrichment, efficient thermal desorption, and gold-mediated charge-hole separation, resulting in a ∼300% increase in AC signal intensity. This enabled the selective detection of over ten medium- and long-chain ACs that were previously undetectable using unmodified SiNWs. The FS IS method incorporates over 30 derivatized AC species, enabling simultaneous quantification with detection limits below 0.01 μmol/L, surpassing the sensitivity of traditional FI-MS. The platform delivers spike recovery rates of 96-112% and supports high-throughput analysis, processing each sample within seconds. Validation against FI-ESI-MS/MS in both urine and dried blood spot samples demonstrated excellent agreement (ρ > 0.95) and effectively identified IEM patient profiles via statistically significant AC elevations. With strong intra- and interbatch precision (median RSD < 12.5%) and substrate stability exceeding one month, this EALDI-MS/FS IS workflow provides a high-throughput, high-coverage, and quantitatively robust solution for clinical AC profiling and newborn screening.

Subjects

MeSH terms (MEDLINE)

CarnitineSpectrometry, Mass, Matrix-Assisted Laser Desorption-IonizationHumansGoldLimit of DetectionStatic ElectricityNanowiresMetal NanoparticlesReproducibility of ResultsSiliconAdsorptionReference StandardsSulfonic AcidsInfant, Newborn

Substances

CarnitineacylcarnitineGoldSiliconSulfonic Acids

Authors and institutions

  • Institution of Analytical Chemistry, Department of Chemistry, Zhejiang University, Hangzhou, Zhejiang 310058, China.
  • Sir Run Run Shaw Hospital, School of Medicine, Zhejiang University, Hangzhou, Zhejiang 310016, China.
  • Zhejiang Key Laboratory of Multi-omics Precision Diagnosis and Treatment of Liver Diseases, Hangzhou, Zhejiang 310016, China.
  • First People's Hospital Affiliated to Westlake University, Hangzhou, Zhejiang 310006, China.
  • Children's Hospital, School of Medicine, Zhejiang University, Hangzhou, Zhejiang 310052, China.

ORCID profiles: Jianmin Wu

Funding

  • National Natural Science Foundation of China

Cite

APA

Cao, S., Jiang, X., Chen, X., Qu, X., & Wu, J. (2025). Integrating Electrostatic Adsorption-Laser Desorption/Ionization-MS with a Derivative Full-Spectrum Internal Standard Approach for Acylcarnitine Quantification in Clinical Samples. Journal of the American Society for Mass Spectrometry. https://doi.org/10.1021/jasms.5c00136

Vancouver

Cao S, Jiang X, Chen X, Qu X, Wu J. Integrating Electrostatic Adsorption-Laser Desorption/Ionization-MS with a Derivative Full-Spectrum Internal Standard Approach for Acylcarnitine Quantification in Clinical Samples. Journal of the American Society for Mass Spectrometry. 2025. doi:10.1021/jasms.5c00136

BibTeX
@article{Cao2025,
  author = {Cao, Shuo and Jiang, Xinrong and Chen, Xiaoming and Qu, Xuetong and Wu, Jianmin},
  title = {Integrating Electrostatic Adsorption-Laser Desorption/Ionization-MS with a Derivative Full-Spectrum Internal Standard Approach for Acylcarnitine Quantification in Clinical Samples},
  journal = {Journal of the American Society for Mass Spectrometry},
  year = {2025},
  doi = {10.1021/jasms.5c00136}
}
Start for free →