A Novel Electrochemical Aptasensors Utilizing AuNW/AuNC/PAA Nanocomposite for Label‐Free Detection of IL‐6 in Human and Mammalian Culture Serum
ChemBioChem · 2025
DOI: 10.1002/cbic.202500596 ↗Kurz gefasst
Fachartikel in der Zeitschrift ChemBioChem, 2025. Verfasst von Mohd-Akmal Hamizan und 4 weiteren Autor:innen. Beteiligte Einrichtung: PAPRSB Institute of Health Sciences, Universiti Brunei Darussalam, Jalan Tungku Link, Gadong, BE1410, Brunei. Hauptthemen laut MEDLINE: Interleukin-6, Aptamers, Nucleotide, Gold, Electrochemical Techniques. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 53 Literaturangaben. Gefördert von: Ministry of Education of Brunei Darussalam, Universiti Brunei Darussalam, University of Brunei Darussalam.
Abstract (Originalsprache)
A versatile and highly sensitive sensing platform has been developed by incorporating a nanocomposite of gold nanowire (AuNW), gold nanocolloid (AuNC), and polyacrylamide (PAA) onto the surface of a screen‐printed carbon electrode (SPCE). This innovative approach is designed for the efficient detection of interleukin‐6 (IL‐6) in human serum and mammalian cell culture. The synthesized gold nanocomposite enhanced the SPCE's electrochemical signal via high conductivity, increased the electroactive surface for efficient electron transfer, and enabled thiolated aptamer immobilization through AuS bonds. In this regard, the AuNW/AuNC/PAA nanocomposite and thiolated IL‐6 aptamers were used to construct an IL‐6 aptasensor for sensitive and selective detection of IL‐6 using differential pulse voltammetry (DPV) in 5 mM [Fe(CN) 6 ] 3−/4− as a redox probe. The fabricated aptasensor demonstrated sensitive detection of IL‐6, with a detection range of 0.1–1000 pg mL −1 and a limit of detection (LOD) of 0.1 pg mL −1 . Moreover, the developed IL‐6 aptasensor exhibited excellent stability, reproducibility, and selectivity. Its applicability was validated by IL‐6 detection in human serum, showing 93.9%–104.8% recovery. Additionally, IL‐6 levels in cell culture media were tested using both the aptasensor and a commercial ELISA kit, showing only a 1.38% difference, further confirming its reliability.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- PAPRSB Institute of Health Sciences, Universiti Brunei Darussalam, Jalan Tungku Link, Gadong, BE1410, Brunei.
- Biosensors and Nanobiotechnology Laboratory, Universiti Brunei Darussalam, Jalan Tungku Link, Gadong, BE1410, Brunei.
ORCID-Profile: Minhaz Uddin Ahmed, Noor Faizah Mohd-Naim
Förderung
- Ministry of Education of Brunei Darussalam
- Universiti Brunei Darussalam
- University of Brunei Darussalam
Zitieren
APA
Hamizan, M. A., Ansari, M. A., Kareem, F., Ahmed, M. U., & Mohd-Naim, N. F. (2025). A Novel Electrochemical Aptasensors Utilizing AuNW/AuNC/PAA Nanocomposite for Label‐Free Detection of IL‐6 in Human and Mammalian Culture Serum. ChemBioChem. https://doi.org/10.1002/cbic.202500596
Vancouver
Hamizan MA, Ansari MA, Kareem F, Ahmed MU, Mohd-Naim NF. A Novel Electrochemical Aptasensors Utilizing AuNW/AuNC/PAA Nanocomposite for Label‐Free Detection of IL‐6 in Human and Mammalian Culture Serum. ChemBioChem. 2025. doi:10.1002/cbic.202500596
BibTeX
@article{Hamizan2025,
author = {Hamizan, Mohd-Akmal and Ansari, Mohd Afaque and Kareem, Faheem and Ahmed, Minhaz Uddin and Mohd-Naim, Noor Faizah},
title = {A Novel Electrochemical Aptasensors Utilizing AuNW/AuNC/PAA Nanocomposite for Label‐Free Detection of IL‐6 in Human and Mammalian Culture Serum},
journal = {ChemBioChem},
year = {2025},
doi = {10.1002/cbic.202500596}
}
EUVIMED