Fachartikel in der Zeitschrift Journal of the American Society for Mass Spectrometry, 2024. Verfasst von Yukai Wang und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry, Faculty of Science, University of British Columbia, Vancouver Campus, 2036 Main Mall, Vancouver V6T 1Z1, BC, Canada. Hauptthemen laut MEDLINE: Breath Tests, Software, Algorithms. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 60 Literaturangaben. Gefördert von: Basic and Applied Basic Research Foundation of Guangdong Province, National Natural Science Foundation of China, University of British Columbia.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Nontargeted breath analysis in real time using high-resolution mass spectrometry (HRMS) is a promising approach for high coverage profiling of metabolites in human exhaled breath. However, the information-rich and unique non-Gaussian metabolic signal shapes of real-time HRMS-based data pose a significant challenge for efficient data processing. This work takes a typical real-time HRMS technique as an example, i.e. secondary electrospray ionization high-resolution mass spectrometry (SESI-HRMS), and presents BreathXplorer, an open-source Python package designed for the processing of real-time exhaled breath data comprising multiple exhalations. BreathXplorer is composed of four main modules. The first module applies either a topological algorithm or a Gaussian mixture model (GMM) to determine the start and end points of each exhalation. Next, density-based spatial clustering of applications with noise (DBSCAN) is employed to cluster m/z values belonging to the same metabolic feature, followed by applying an intensity relative standard deviation (RSD) filter to extract real breath metabolic features. BreathXplorer also offers functions of (1) feature alignment across the samples and (2) associating MS/MS spectra with their corresponding metabolic features for downstream compound annotation. Manual inspection of the metabolic features extracted from SESI-HRMS breath data suggests that BreathXplorer can achieve 100% accuracy in identifying the start and end points of each exhalation and acquire accurate quantitative measurements of each breath feature. In a proof-of-concept study on exercise breathomics using SESI-HRMS, BreathXplorer successfully reveals the significantly changed metabolites that are pertinent to exercise. BreathXplorer is publicly available on GitHub (https://github.com/HuanLab/breathXplorer). It provides a powerful and convenient-to-use tool for the researchers to process breathomics data obtained by directly analysis using HRMS.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Breath TestsSoftwareAlgorithmsHumansExhalationSpectrometry, Mass, Electrospray IonizationTandem Mass SpectrometryMetabolomics

Autor:innen und Institutionen

  • Department of Chemistry, Faculty of Science, University of British Columbia, Vancouver Campus, 2036 Main Mall, Vancouver V6T 1Z1, BC, Canada.
  • Institute of Mass Spectrometry and Atmospheric Environment, Guangdong Provincial Key Laboratory of Speed Capability Research, Jinan University, Guangzhou 510632, China.
  • Guangdong Provincial Key Laboratory of Speed Capability Research; Su Bingtian Center for Speed Research and Training; School of Physical Education, Jinan University, Guangzhou 510632, China.
  • Guangdong A-HealthX Technologies Co., Ltd, Dongguan 523830, China.

ORCID-Profile: Xue Li, Tao Huan

Förderung

  • Basic and Applied Basic Research Foundation of Guangdong Province
  • National Natural Science Foundation of China
  • University of British Columbia

Zitieren

APA

Wang, Y., Tang, Z., Zhao, T., Yang, J., Zhang, W., Li, X., & Huan, T. (2024). BreathXplorer: Processing Online Breathomics Data Generated from Direct Analysis Using High-Resolution Mass Spectrometry. Journal of the American Society for Mass Spectrometry. https://doi.org/10.1021/jasms.4c00152

Vancouver

Wang Y, Tang Z, Zhao T, Yang J, Zhang W, Li X, et al. BreathXplorer: Processing Online Breathomics Data Generated from Direct Analysis Using High-Resolution Mass Spectrometry. Journal of the American Society for Mass Spectrometry. 2024. doi:10.1021/jasms.4c00152

BibTeX
@article{Wang2024,
  author = {Wang, Yukai and Tang, Zhifeng and Zhao, Tingting and Yang, Jianming and Zhang, Wei and Li, Xue and Huan, Tao},
  title = {BreathXplorer: Processing Online Breathomics Data Generated from Direct Analysis Using High-Resolution Mass Spectrometry},
  journal = {Journal of the American Society for Mass Spectrometry},
  year = {2024},
  doi = {10.1021/jasms.4c00152}
}
Kostenlos starten →