Alternative electrolyte solutions for untargeted breath metabolomics using secondary‐electrospray ionization high‐resolution mass spectrometry
Rapid Communications in Mass Spectrometry · 2024
DOI: 10.1002/rcm.9714 ↗Kurz gefasst
Fachartikel in der Zeitschrift Rapid Communications in Mass Spectrometry, 2024. Verfasst von Cedric Wüthrich und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry and Applied Biosciences, ETHZ, Zurich, Switzerland. Hauptthemen laut MEDLINE: Spectrometry, Mass, Electrospray Ionization, Metabolomics. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 42 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Ascher Trust, Agroscope.
Abstract (Originalsprache)
Rationale
Secondary‐electrospray ionization (SESI) coupled with high‐resolution mass spectrometry is a powerful tool for the discovery of biomarkers in exhaled breath. A primary electrospray consisting of aqueous formic acid (FA) is currently used to charge the volatile organic compounds in breath. To investigate whether alternate electrospray compositions could enable different metabolite coverage and sensitivities, the electrospray dopants NaI and AgNO 3 were tested.
Methods
In a proof‐of‐principle manner, the exhaled breath of one subject was analyzed repeatedly with different electrospray solutions and with the help of a spectral stitching technique. Capillary diameter and position were optimized to achieve proper detection of exhaled breath. The detected features were then compared using formula annotation. Using an evaporation‐based gas standard system, the signal response of the different solutions was probed.
Results
Principal component analysis revealed a substantial difference in features detected with AgNO 3 . With silver, more sulfur‐containing features and more unsaturated hydrocarbon compounds were detected. Furthermore, more primary amines were potentially ionized, as indicated by van Krewelen diagrams. In total, twice as many features were unique to AgNO 3 than for other electrospray dopants. Using gas standards at known concentrations, the high sensitivity of FA as a dopant was demonstrated but also indicated alternate sensitivities of the other electrospray solutions.
Conclusions
This work demonstrated the potential of AgNO 3 as a complementary dopant for further biomarker discovery in SESI‐based breath analysis.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Department of Chemistry and Applied Biosciences, ETHZ, Zurich, Switzerland.
ORCID-Profile: Stamatios Giannoukos
Förderung
- Ascher Trust
- Agroscope
Zitieren
APA
Wüthrich, C., Zenobi, R., & Giannoukos, S. (2024). Alternative electrolyte solutions for untargeted breath metabolomics using secondary‐electrospray ionization high‐resolution mass spectrometry. Rapid Communications in Mass Spectrometry. https://doi.org/10.1002/rcm.9714
Vancouver
Wüthrich C, Zenobi R, Giannoukos S. Alternative electrolyte solutions for untargeted breath metabolomics using secondary‐electrospray ionization high‐resolution mass spectrometry. Rapid Communications in Mass Spectrometry. 2024. doi:10.1002/rcm.9714
BibTeX
@article{Wthrich2024,
author = {Wüthrich, Cedric and Zenobi, Renato and Giannoukos, Stamatios},
title = {Alternative electrolyte solutions for untargeted breath metabolomics using secondary‐electrospray ionization high‐resolution mass spectrometry},
journal = {Rapid Communications in Mass Spectrometry},
year = {2024},
doi = {10.1002/rcm.9714}
}
EUVIMED