EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Modified Ion Source for the Improved Collisional Activation of Protein Complexes

Robert L Schrader iD, Thomas E Walker, David H Russell iD

Journal of the American Society for Mass Spectrometry · 2023

DOI: 10.1021/jasms.3c00071 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of the American Society for Mass Spectrometry, 2023. Verfasst von Robert L Schrader und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry, Texas A&M University, College Station, Texas 77843, United States. Hauptthemen laut MEDLINE: Mass Spectrometry. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NIGMS NIH HHS, SCIEX, National Institutes of Health.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The analysis of large molecules is challenging, as they often have salts and adducts retained through the electrospray process, which increase the observed mass and compromise the achievable mass resolution. Mild collisional activation has been shown to be very effective for the removal of adducts and increases both measurement accuracy and mass resolution of large (>100 kDa) protein complexes. Collisionally activated protein ions are more completely desolvated due to the increased number of collisions when trapped following activation. A short square quadrupole maintained at 300 mTorr by a mechanical pump was added between the ion funnel and transmission quadrupole. This configuration and operation effectively removed adducts from the 800 kDa tetradecamer GroEL as well as fragmented smaller protein complexes like C-reactive protein. Due to the gas high pressure, ions of low size-to-charge ratio, such as those in charge reducing buffers, had low ejection efficiency. We show that segmenting the quadrupole rods greatly improves signal intensity for charge reduced GroEL D398A mutant compared to nonsegmented rods when operating at high pressure.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Mass SpectrometryProteinsIons

Stichwörter der Autor:innen

GroELOrbitrap mass spectrometryion trapnative mass spectrometryquadrupole mass spectrometry

Substanzen

ProteinsIons

Autor:innen und Institutionen

  • Department of Chemistry, Texas A&M University, College Station, Texas 77843, United States.

ORCID-Profile: Robert L Schrader, David H Russell

Förderung

  • NIGMS NIH HHS
  • SCIEX
  • National Institutes of Health

Zitieren

APA

Schrader, R. L., Walker, T. E., & Russell, D. H. (2023). Modified Ion Source for the Improved Collisional Activation of Protein Complexes. Journal of the American Society for Mass Spectrometry. https://doi.org/10.1021/jasms.3c00071

Vancouver

Schrader RL, Walker TE, Russell DH. Modified Ion Source for the Improved Collisional Activation of Protein Complexes. Journal of the American Society for Mass Spectrometry. 2023. doi:10.1021/jasms.3c00071

BibTeX
@article{Schrader2023,
  author = {Schrader, Robert L and Walker, Thomas E and Russell, David H},
  title = {Modified Ion Source for the Improved Collisional Activation of Protein Complexes},
  journal = {Journal of the American Society for Mass Spectrometry},
  year = {2023},
  doi = {10.1021/jasms.3c00071}
}
Kostenlos starten →