EUVIMEDOpdag EUVIMED
Open access · CC BY 4.0

Modified Ion Source for the Improved Collisional Activation of Protein Complexes

Robert L Schrader iD, Thomas E Walker, David H Russell iD

Journal of the American Society for Mass Spectrometry · 2023

DOI: 10.1021/jasms.3c00071 ↗

At a glance

Journal article in Journal of the American Society for Mass Spectrometry, 2023. Written by Robert L Schrader and 2 co-authors. Institution: Department of Chemistry, Texas A&M University, College Station, Texas 77843, United States. Major MEDLINE topics: Mass Spectrometry. Cited 3 times so far (Crossref); 24 references. The full text is freely available (open access, CC BY 4.0). Funded by: NIGMS NIH HHS, SCIEX, National Institutes of Health.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

The analysis of large molecules is challenging, as they often have salts and adducts retained through the electrospray process, which increase the observed mass and compromise the achievable mass resolution. Mild collisional activation has been shown to be very effective for the removal of adducts and increases both measurement accuracy and mass resolution of large (>100 kDa) protein complexes. Collisionally activated protein ions are more completely desolvated due to the increased number of collisions when trapped following activation. A short square quadrupole maintained at 300 mTorr by a mechanical pump was added between the ion funnel and transmission quadrupole. This configuration and operation effectively removed adducts from the 800 kDa tetradecamer GroEL as well as fragmented smaller protein complexes like C-reactive protein. Due to the gas high pressure, ions of low size-to-charge ratio, such as those in charge reducing buffers, had low ejection efficiency. We show that segmenting the quadrupole rods greatly improves signal intensity for charge reduced GroEL D398A mutant compared to nonsegmented rods when operating at high pressure.

Subjects

MeSH terms (MEDLINE)

Mass SpectrometryProteinsIons

Author keywords

GroELOrbitrap mass spectrometryion trapnative mass spectrometryquadrupole mass spectrometry

Substances

ProteinsIons

Authors and institutions

  • Department of Chemistry, Texas A&M University, College Station, Texas 77843, United States.

ORCID profiles: Robert L Schrader, David H Russell

Funding

  • NIGMS NIH HHS
  • SCIEX
  • National Institutes of Health

Cite

APA

Schrader, R. L., Walker, T. E., & Russell, D. H. (2023). Modified Ion Source for the Improved Collisional Activation of Protein Complexes. Journal of the American Society for Mass Spectrometry. https://doi.org/10.1021/jasms.3c00071

Vancouver

Schrader RL, Walker TE, Russell DH. Modified Ion Source for the Improved Collisional Activation of Protein Complexes. Journal of the American Society for Mass Spectrometry. 2023. doi:10.1021/jasms.3c00071

BibTeX
@article{Schrader2023,
  author = {Schrader, Robert L and Walker, Thomas E and Russell, David H},
  title = {Modified Ion Source for the Improved Collisional Activation of Protein Complexes},
  journal = {Journal of the American Society for Mass Spectrometry},
  year = {2023},
  doi = {10.1021/jasms.3c00071}
}
Start for free →