EUVIMEDEUVIMED entdecken
Crossref

Photothermal Paper-Based Microfluidic Analytical Device Integrated with Carbon Nanomaterials and Molecularly Imprinted Polymers for Sensitive Perfluorooctanesulfonate Quantification

Kawin Khachornsakkul iD, Thithawat Trakoolwilaiwan, Ruben Del-Rio-Ruiz, Elliot Friesen iD, Wijitar Dungchai iD, Tapparath Leelasattarathkul

ACS Sensors · 25.07.2025 · 10 (7) · 5008-5018

DOI: 10.1021/acssensors.5c00940 ↗

Kurz gefasst

Fachartikel in der Zeitschrift ACS Sensors, online erschienen am 01.07.2025. Verfasst von Kawin Khachornsakkul und 5 weiteren Autor:innen. Beteiligte Einrichtung: Division of Chemistry, Department of Science, Faculty of Science and Technology, Rajamangala University of Technology Krungthep, Bangkok 10120, Thail…. Hauptthemen laut MEDLINE: Fluorocarbons, Alkanesulfonic Acids, Molecularly Imprinted Polymers, Carbon. Die Arbeit wurde bisher 17-mal zitiert (Crossref) und nennt 65 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The global prevalence of perfluoroalkyl and polyfluoroalkyl substance (PFAS) contamination highlights the need for sensitive, accessible, simple, and cost-effective analytical tools. In this article, we present the first photothermal-based microfluidic paper-based analytical device (PT-μPAD) for the detection of perfluorooctanesulfonate (PFOS), one of the most widespread PFAS, in various matrices, including water, food, and human samples. By integration of a molecularly imprinted polymer (MIP) with carbon dots (CDs), the device achieves selective and sensitive PFOS monitoring by measuring the temperature change on the μPAD sensor. Additionally, the detection signal is rapidly obtained via a wireless near-field communication (NFC) system embedded in a portable and user-friendly platform. Under optimization, the developed sensor delivers a linear range between 1.5 and 7.0 pg mL-1 (R2 = 0.9989) and a detection limit (limit of detection (LOD)) of 7.0 fg mL-1. Our developed sensor also exhibits high selectivity, with no observed interferent effects. The method also demonstrates remarkable accuracy and precision for PFOS quantification across real-world samples, achieving recovery percentages of 92.5-110.0% and the highest relative standard deviation (RSD) of 7.3%. Correspondingly, the results obtained using our method are comparable to those from the high-performance liquid chromatography-mass spectrometry (HPLC-MS/MS) method, as confirmed by a 95% confidence level in the t test analysis. Therefore, this sensor is well-suited for PFOS monitoring across various sample matrices, offering key advantages, such as simplicity, cost-effectiveness, portability, and ease of use by unskilled operators. Overall, this approach can be extended to the detection of other target molecules through MIP modification, showing its versatility. Furthermore, this concept holds great potential for broader applications, including medical point-of-care (POC) diagnostics and prognostics, on-site environmental analysis, and food safety.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

FluorocarbonsAlkanesulfonic AcidsMolecularly Imprinted PolymersCarbonPaperLab-On-A-Chip DevicesNanostructuresMicrofluidic Analytical TechniquesLimit of DetectionHumansWater Pollutants, Chemical

Stichwörter der Autor:innen

carbon dots (CDs)microfluidic paper-based analytical devices (μPADs)molecularly imprinted polymers (MIPs)per- and polyfluoroalkyl substance (PFAS)perfluorooctanesulfonate (PFOS)photothermal detection

Substanzen

FluorocarbonsAlkanesulfonic Acidsperfluorooctane sulfonic acidMolecularly Imprinted PolymersCarbonWater Pollutants, Chemical

Autor:innen und Institutionen

  • Division of Chemistry, Department of Science, Faculty of Science and Technology, Rajamangala University of Technology Krungthep, Bangkok 10120, Thailand.
  • Department of Electrical and Computer Engineering, Tufts University, Medford, Massachusetts 02155, United States.
  • Department of Chemistry, Faculty of Science, King Mongkut's University of Technology Thonburi, Prachautid Road, Thungkru, Bangkok 10140, Thailand.
  • National Nanotechnology Center (NANOTEC), National Science and Technology Development Agency (NSTDA), Khlong Luang, Pathum Thani 12120, Thailand.
  • School of Engineering, Technology, and Aeronautics, Southern New Hampshire University, Manchester, New Hampshire 03106, United States.

ORCID-Profile: Kawin Khachornsakkul, Elliot Friesen, Wijitar Dungchai

Zitieren

APA

Khachornsakkul, K., Trakoolwilaiwan, T., Del-Rio-Ruiz, R., Friesen, E., Dungchai, W., & Leelasattarathkul, T. (2025). Photothermal Paper-Based Microfluidic Analytical Device Integrated with Carbon Nanomaterials and Molecularly Imprinted Polymers for Sensitive Perfluorooctanesulfonate Quantification. ACS Sensors, 10(7), 5008-5018. https://doi.org/10.1021/acssensors.5c00940

Vancouver

Khachornsakkul K, Trakoolwilaiwan T, Del-Rio-Ruiz R, Friesen E, Dungchai W, Leelasattarathkul T. Photothermal Paper-Based Microfluidic Analytical Device Integrated with Carbon Nanomaterials and Molecularly Imprinted Polymers for Sensitive Perfluorooctanesulfonate Quantification. ACS Sensors. 2025;10(7):5008-5018. doi:10.1021/acssensors.5c00940

BibTeX
@article{Khachornsakkul2025,
  author = {Khachornsakkul, Kawin and Trakoolwilaiwan, Thithawat and Del-Rio-Ruiz, Ruben and Friesen, Elliot and Dungchai, Wijitar and Leelasattarathkul, Tapparath},
  title = {Photothermal Paper-Based Microfluidic Analytical Device Integrated with Carbon Nanomaterials and Molecularly Imprinted Polymers for Sensitive Perfluorooctanesulfonate Quantification},
  journal = {ACS Sensors},
  year = {2025},
  volume = {10},
  number = {7},
  pages = {5008--5018},
  doi = {10.1021/acssensors.5c00940}
}
Kostenlos starten →