EUVIMEDEUVIMED entdecken
Crossref

Simple, Affordable Distance-Based Paper Analytical Device for the Quantitative Perfluorooctane Sulfonate Detection in Drinking Water and Beverage Samples

Kawin Khachornsakkul iD, Tapparath Leelasattarathkul, Waleed Alahmad iD

ACS Sensors · 24.07.2026 · 11 (7) · 6346-6355

DOI: 10.1021/acssensors.6c01498 ↗

Kurz gefasst

Fachartikel in der Zeitschrift ACS Sensors, online erschienen am 27.06.2026. Verfasst von Kawin Khachornsakkul und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry, Faculty of Science, Chulalongkorn University, Bangkok10330, Thailand. Hauptthemen laut MEDLINE: Fluorocarbons, Alkanesulfonic Acids, Drinking Water, Paper. Die Arbeit nennt 59 Literaturangaben. Gefördert von: Chulalongkorn University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The emerging global concern over contamination of water supplies and food samples with per- and polyfluoroalkyl substances (PFAS) emphasizes the need to develop simple and cost-effective analytical methods for their monitoring. This article introduces the distance-based paper analytical devices (dPADs) for the detection of perfluorooctanesulfonate (PFOS) levels in consumable samples. This method leverages the oxidative decomposition of PFOS to deplete the generated hydroxyl radicals (•OH) from silver nanoparticles (AgNPs) and hydrogen peroxide (H2O2), which subsequently reduces the oxidation reaction of 3,3′,5,5′-tetramethylbenzidine (TMB) to form oxidized TMB (oxTMB) on the paper substrate. Accordingly, PFOS levels can be quantified through changes in the uncolored distance length observable by the naked eye. Additionally, the utilization of the designed hydrophobic wax lines in the delay channel of the dPAD sensor enhances PFOS detection. The sensor exhibits a linear range of 3.0-15.0 ng L–1 (R2 = 0.9972) with a detection limit (LOD) of 3.0 ng L–1. The assay shows excellent accuracy and precision in monitoring PFOS in drinking water and beverage samples, with the recoveries ranging between 95.0 and 107.5% and the highest RSD of 7.89%. Similarly, the results obtained from our method are consistent with those of the high-performance liquid chromatography-mass spectrometry (HPLC-MS/MS) method, as confirmed by a 95% confidence level in t-test analysis. Notably, to the best of our knowledge, this is the first demonstration of the dPAD technique for PFOS detection, showing an effective and promising approach for real-world applications. Furthermore, the method is cheaper and easier to use than previous methods that rely on expensive instruments and require skilled personnel to operate them. Overall, the developed dPAD sensor has great potential as an instrument-free analytical technique for sensitive PFOS monitoring in water and beverage samples, enabling rapid assessment of food quality in both resource-limited settings and developing countries.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

FluorocarbonsAlkanesulfonic AcidsDrinking WaterPaperBeveragesWater Pollutants, ChemicalLimit of DetectionMetal NanoparticlesFood Contamination

Stichwörter der Autor:innen

distance-based paper analytical devices (dPADs)food qualitypaper microfluidicsper- and polyfluoroalkyl substance (PFAS)perfluorooctane sulfonate (PFOS)

Substanzen

FluorocarbonsAlkanesulfonic Acidsperfluorooctane sulfonic acidDrinking WaterWater Pollutants, Chemical

Autor:innen und Institutionen

  • Department of Chemistry, Faculty of Science, Chulalongkorn University, Bangkok10330, Thailand.
  • Division of Chemistry, Department of Science, Faculty of Science and Technology, Rajamangala University of Technology Krungthep, Bangkok10120, Thailand.

ORCID-Profile: Kawin Khachornsakkul, Waleed Alahmad

Förderung

  • Chulalongkorn University

Zitieren

APA

Khachornsakkul, K., Leelasattarathkul, T., & Alahmad, W. (2026). Simple, Affordable Distance-Based Paper Analytical Device for the Quantitative Perfluorooctane Sulfonate Detection in Drinking Water and Beverage Samples. ACS Sensors, 11(7), 6346-6355. https://doi.org/10.1021/acssensors.6c01498

Vancouver

Khachornsakkul K, Leelasattarathkul T, Alahmad W. Simple, Affordable Distance-Based Paper Analytical Device for the Quantitative Perfluorooctane Sulfonate Detection in Drinking Water and Beverage Samples. ACS Sensors. 2026;11(7):6346-6355. doi:10.1021/acssensors.6c01498

BibTeX
@article{Khachornsakkul2026,
  author = {Khachornsakkul, Kawin and Leelasattarathkul, Tapparath and Alahmad, Waleed},
  title = {Simple, Affordable Distance-Based Paper Analytical Device for the Quantitative Perfluorooctane Sulfonate Detection in Drinking Water and Beverage Samples},
  journal = {ACS Sensors},
  year = {2026},
  volume = {11},
  number = {7},
  pages = {6346--6355},
  doi = {10.1021/acssensors.6c01498}
}
Kostenlos starten →