EUVIMEDEUVIMED entdecken
Crossref

Adhered-3D paper microfluidic analytical device based on oxidase-mimicking activity of Co-doped carbon dots nanozyme for point-of-care testing of alkaline phosphatase

Jing Guo, Jing Zhang, Xia Tong

Analytica Chimica Acta · 2024

DOI: 10.1016/j.aca.2024.343378 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytica Chimica Acta, 2024. Verfasst von Jing Guo und 2 weiteren Autor:innen. Beteiligte Einrichtung: School of Physics and Information Engineering, Shanxi Normal University, Taiyuan, 031000, China. Hauptthemen laut MEDLINE: Alkaline Phosphatase, Carbon, Paper, Quantum Dots. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 43 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Paper-based microfluidic analytical devices (μPADs) have become promising alternatives to clinical laboratory-based methods for point-of-care testing (POCT) of biomarkers in family care and resource-limited communities. Here, Co-doped carbon dots (Co-CDs) nanozyme with outstanding oxidase-mimicking catalytic activity and red fluorescent emission were prepared, and combined adhered-3D μPAD (A-3D μPAD) to monitor facilely alkaline phosphatase (ALP) level in whole blood samples. Co-CDs catalyzed the oxidization of nonfluorescent o-phenylenediamine (OPD) into 2,3-diaminophenazine (oxOPD) with yellow fluorescent emission due to the generation of tremendous O2•- species. With addition of ALP, ALP hydrolyzed l-ascorbic acid 2-phosphate into ascorbic acid, and the latter was oxidized by Co-CDs, then reacted with OPD to form blue fluorescent emission 3-(dihydroxyethyl)furo [3,4-b]quinoxaline-1-one (DFQ). Both DFQ and oxOPD quenched the fluorescence intensity of Co-CDs via inner-filter effect. The cascade reaction of ALP/Co-CDs was incorporated into A-3D μPAD based on above sensing principles. A-3D μPAD enabled sample pretreatment, cascade reaction and signal output, and integrated portable minimized device and smartphone for visual ALP detection. The linear range and limit of detection for ALP were 0.5-150 U L-1 and 0.1 U L-1, respectively, and the color varied from red, yellow to blue. The detection results for whole blood samples were consistent with biochemical detector. The efficiency, disposability, practicality and low-cost of A-3D μPAD can be extended to determine various biomarkers, and provided technical support for nanozyme applications in POCT environments.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Alkaline PhosphataseCarbonPaperQuantum DotsLab-On-A-Chip DevicesPoint-of-Care TestingHumansLimit of DetectionOxidoreductasesPhenylenediamines

Stichwörter der Autor:innen

Adhered-3D paper-based microfluidic analytical deviceAlkaline phosphataseCo-doped carbon dotsFluorometricOxidase-mimicking nanozyme

Substanzen

Alkaline PhosphataseCarbonOxidoreductases1,2-diaminobenzenePhenylenediamines

Autor:innen und Institutionen

  • School of Physics and Information Engineering, Shanxi Normal University, Taiyuan, 031000, China.
  • School of Chemistry and Materials Science, Shanxi Normal University, Taiyuan, 031000, China.
  • Stem Cell Translation Laboratory, Shanxi Bethune Hospital, Shanxi Academy of Medical Sciences, Third Hospital of Shanxi Medical University, Tongji Shanxi Hospital, Taiyuan, 030032, China. Electronic address: xiatongcsu@…

Zitieren

APA

Guo, J., Zhang, J., & Tong, X. (2024). Adhered-3D paper microfluidic analytical device based on oxidase-mimicking activity of Co-doped carbon dots nanozyme for point-of-care testing of alkaline phosphatase. Analytica Chimica Acta. https://doi.org/10.1016/j.aca.2024.343378

Vancouver

Guo J, Zhang J, Tong X. Adhered-3D paper microfluidic analytical device based on oxidase-mimicking activity of Co-doped carbon dots nanozyme for point-of-care testing of alkaline phosphatase. Analytica Chimica Acta. 2024. doi:10.1016/j.aca.2024.343378

BibTeX
@article{Guo2024,
  author = {Guo, Jing and Zhang, Jing and Tong, Xia},
  title = {Adhered-3D paper microfluidic analytical device based on oxidase-mimicking activity of Co-doped carbon dots nanozyme for point-of-care testing of alkaline phosphatase},
  journal = {Analytica Chimica Acta},
  year = {2024},
  doi = {10.1016/j.aca.2024.343378}
}
Kostenlos starten →