EUVIMEDEUVIMED entdecken
Crossref

A Glycosyl-Imprinted Sensor Used for Accurate Classification and Quantification of Breast Cancer-Derived Exosomes by Electrochemiluminescence Detection of Two Glycoproteins at Dual Potentials

Kui Luo, Zejun Jiang, Ling Li, Lijuan Lin, Tao Qin, Jianping Li iD

ACS Sensors · 22.08.2025 · 10 (8) · 5528-5538

DOI: 10.1021/acssensors.4c03666 ↗

Kurz gefasst

Fachartikel in der Zeitschrift ACS Sensors, online erschienen am 19.07.2025. Verfasst von Kui Luo und 5 weiteren Autor:innen. Beteiligte Einrichtung: College of Environmental Science and Engineering, Guilin University of Technology, Guilin 541004, China. Hauptthemen laut MEDLINE: Exosomes, Breast Neoplasms, Mucin-1, Electrochemical Techniques. Die Arbeit wurde bisher 16-mal zitiert (Crossref) und nennt 57 Literaturangaben. Gefördert von: Guangxi Key Laboratory of Electrochemical and Magnetochemical Functional Materials, National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Early diagnosis of breast cancer remains a challenge. Tumor-derived exosomes are considered ideal biomarkers for liquid biopsies in early diagnosis because they carry genetic materials and proteins similar to those of tumor cells. In this paper, a glycosyl-imprinted electrochemiluminescence sensor was constructed as a specificity hunter to capture breast cancer exosomes by adsorbing the polysaccharides of exosomes PD-L1 on a glycosyl-imprinted polymer (GIP); then, PD-L1 and MUC1 were specifically labeled with the aptamer probes of Au@luminol-PD-L1 and Au@g-C3N4-MUC1, respectively. Breast cancer exosomes were identified by the GIP membrane, and then the potential-resolved ECL signals of the probes labeled on PD-L1 and MUC1 at cathodic (-1.4 V) and anodic (+0.7 V) potentials were recorded, respectively. The platform enables quantitative analysis of exosomes and the detection of exosome marker proteins PD-L1 and MUC1 in breast cancer. The determination ranges for PD-L1 and MUC1 were 2.10 × 10-4 to 2.10 pg/mL and 1.88 × 10-3 to 18.8 pg/mL, respectively, and the detection limits of PD-L1 and MUC1 were 0.105 fg/mL and 1.28 fg/mL, respectively. The determination range for exosomes was 2.36 × 103 to 2.36 × 107 exosomes/mL, and the detection limits of exosomes were 1.620 × 103 and 1.586 × 103 exosomes/mL via the signals of aptamer probes labeled on Au@luminol-PD-L1 and Au@g-C3N4-MUC1, respectively. Based on the simultaneous analysis of the coexistence-specific markers PD-L1 and MUC1 carried by breast cancer-derived exosomes by the GIP sensor, the selectivity for the identification of breast cancer-derived exosomes was improved, thereby greatly expanding the ability of glycosyl imprinting technology to identify breast cancer-derived exosomes and accurately distinguish breast cancer patients from healthy individuals, reducing the risk of false positives and providing a reliable tool for the clinical diagnosis of breast cancer.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ExosomesBreast NeoplasmsMucin-1Electrochemical TechniquesLuminescent MeasurementsB7-H1 AntigenBiosensing TechniquesHumansFemaleAptamers, NucleotideLimit of DetectionMolecular ImprintingGoldBiomarkers, Tumor

Stichwörter der Autor:innen

breast cancerearly diagnosiselectrochemiluminescence sensorexosomeglycosyl imprintingpotential-resolved detection

Substanzen

Mucin-1MUC1 protein, humanB7-H1 AntigenCD274 protein, humanAptamers, NucleotideGoldBiomarkers, Tumor

Autor:innen und Institutionen

  • College of Environmental Science and Engineering, Guilin University of Technology, Guilin 541004, China.
  • College of Chemistry and Bioengineering, Guilin University of Technology, Guilin 541004, China.
  • Affiliated Hospital of Guilin Medical University, Guilin 541001, China.

ORCID-Profile: Jianping Li

Förderung

  • Guangxi Key Laboratory of Electrochemical and Magnetochemical Functional Materials
  • National Natural Science Foundation of China

Zitieren

APA

Luo, K., Jiang, Z., Li, L., Lin, L., Qin, T., & Li, J. (2025). A Glycosyl-Imprinted Sensor Used for Accurate Classification and Quantification of Breast Cancer-Derived Exosomes by Electrochemiluminescence Detection of Two Glycoproteins at Dual Potentials. ACS Sensors, 10(8), 5528-5538. https://doi.org/10.1021/acssensors.4c03666

Vancouver

Luo K, Jiang Z, Li L, Lin L, Qin T, Li J. A Glycosyl-Imprinted Sensor Used for Accurate Classification and Quantification of Breast Cancer-Derived Exosomes by Electrochemiluminescence Detection of Two Glycoproteins at Dual Potentials. ACS Sensors. 2025;10(8):5528-5538. doi:10.1021/acssensors.4c03666

BibTeX
@article{Luo2025,
  author = {Luo, Kui and Jiang, Zejun and Li, Ling and Lin, Lijuan and Qin, Tao and Li, Jianping},
  title = {A Glycosyl-Imprinted Sensor Used for Accurate Classification and Quantification of Breast Cancer-Derived Exosomes by Electrochemiluminescence Detection of Two Glycoproteins at Dual Potentials},
  journal = {ACS Sensors},
  year = {2025},
  volume = {10},
  number = {8},
  pages = {5528--5538},
  doi = {10.1021/acssensors.4c03666}
}
Kostenlos starten →