A Glycosyl-Imprinted Sensor Used for Accurate Classification and Quantification of Breast Cancer-Derived Exosomes by Electrochemiluminescence Detection of Two Glycoproteins at Dual Potentials
ACS Sensors · 22.08.2025 · 10 (8) · 5528-5538
DOI: 10.1021/acssensors.4c03666 ↗Kurz gefasst
Fachartikel in der Zeitschrift ACS Sensors, online erschienen am 19.07.2025. Verfasst von Kui Luo und 5 weiteren Autor:innen. Beteiligte Einrichtung: College of Environmental Science and Engineering, Guilin University of Technology, Guilin 541004, China. Hauptthemen laut MEDLINE: Exosomes, Breast Neoplasms, Mucin-1, Electrochemical Techniques. Die Arbeit wurde bisher 16-mal zitiert (Crossref) und nennt 57 Literaturangaben. Gefördert von: Guangxi Key Laboratory of Electrochemical and Magnetochemical Functional Materials, National Natural Science Foundation of China.
Abstract (Originalsprache)
Early diagnosis of breast cancer remains a challenge. Tumor-derived exosomes are considered ideal biomarkers for liquid biopsies in early diagnosis because they carry genetic materials and proteins similar to those of tumor cells. In this paper, a glycosyl-imprinted electrochemiluminescence sensor was constructed as a specificity hunter to capture breast cancer exosomes by adsorbing the polysaccharides of exosomes PD-L1 on a glycosyl-imprinted polymer (GIP); then, PD-L1 and MUC1 were specifically labeled with the aptamer probes of Au@luminol-PD-L1 and Au@g-C3N4-MUC1, respectively. Breast cancer exosomes were identified by the GIP membrane, and then the potential-resolved ECL signals of the probes labeled on PD-L1 and MUC1 at cathodic (-1.4 V) and anodic (+0.7 V) potentials were recorded, respectively. The platform enables quantitative analysis of exosomes and the detection of exosome marker proteins PD-L1 and MUC1 in breast cancer. The determination ranges for PD-L1 and MUC1 were 2.10 × 10-4 to 2.10 pg/mL and 1.88 × 10-3 to 18.8 pg/mL, respectively, and the detection limits of PD-L1 and MUC1 were 0.105 fg/mL and 1.28 fg/mL, respectively. The determination range for exosomes was 2.36 × 103 to 2.36 × 107 exosomes/mL, and the detection limits of exosomes were 1.620 × 103 and 1.586 × 103 exosomes/mL via the signals of aptamer probes labeled on Au@luminol-PD-L1 and Au@g-C3N4-MUC1, respectively. Based on the simultaneous analysis of the coexistence-specific markers PD-L1 and MUC1 carried by breast cancer-derived exosomes by the GIP sensor, the selectivity for the identification of breast cancer-derived exosomes was improved, thereby greatly expanding the ability of glycosyl imprinting technology to identify breast cancer-derived exosomes and accurately distinguish breast cancer patients from healthy individuals, reducing the risk of false positives and providing a reliable tool for the clinical diagnosis of breast cancer.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- College of Environmental Science and Engineering, Guilin University of Technology, Guilin 541004, China.
- College of Chemistry and Bioengineering, Guilin University of Technology, Guilin 541004, China.
- Affiliated Hospital of Guilin Medical University, Guilin 541001, China.
ORCID-Profile: Jianping Li
Förderung
- Guangxi Key Laboratory of Electrochemical and Magnetochemical Functional Materials
- National Natural Science Foundation of China
Zitieren
APA
Luo, K., Jiang, Z., Li, L., Lin, L., Qin, T., & Li, J. (2025). A Glycosyl-Imprinted Sensor Used for Accurate Classification and Quantification of Breast Cancer-Derived Exosomes by Electrochemiluminescence Detection of Two Glycoproteins at Dual Potentials. ACS Sensors, 10(8), 5528-5538. https://doi.org/10.1021/acssensors.4c03666
Vancouver
Luo K, Jiang Z, Li L, Lin L, Qin T, Li J. A Glycosyl-Imprinted Sensor Used for Accurate Classification and Quantification of Breast Cancer-Derived Exosomes by Electrochemiluminescence Detection of Two Glycoproteins at Dual Potentials. ACS Sensors. 2025;10(8):5528-5538. doi:10.1021/acssensors.4c03666
BibTeX
@article{Luo2025,
author = {Luo, Kui and Jiang, Zejun and Li, Ling and Lin, Lijuan and Qin, Tao and Li, Jianping},
title = {A Glycosyl-Imprinted Sensor Used for Accurate Classification and Quantification of Breast Cancer-Derived Exosomes by Electrochemiluminescence Detection of Two Glycoproteins at Dual Potentials},
journal = {ACS Sensors},
year = {2025},
volume = {10},
number = {8},
pages = {5528--5538},
doi = {10.1021/acssensors.4c03666}
}
EUVIMED