EUVIMEDEUVIMED entdecken
Crossref

Biological Optical Nanocavity-Coupled Electrochemiluminescence Sensor for the Detection of Extracellular Vesicle Glycosylation in Gastric Cancer Diagnosis

Peilin Wang, Zhenrun Li, Wenyan Li, Fangyan Ji, Qiang Ma iD

ACS Sensors · 2026

DOI: 10.1021/acssensors.6c00361 ↗

Kurz gefasst

Fachartikel in der Zeitschrift ACS Sensors, 2026. Verfasst von Peilin Wang und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Analytical Chemistry, College of Chemistry, Jilin University, Changchun 130012, China. Hauptthemen laut MEDLINE: Stomach Neoplasms, Luminescent Measurements, Electrochemical Techniques, Extracellular Vesicles. Die Arbeit wurde bisher 19-mal zitiert (Crossref) und nennt 41 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Education Department of Jilin Province.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Biological membrane curvature not only signifies morphological characteristics but also participates in various physiological processes. Analyzing the relationship between membrane curvature and biomolecules of extracellular vesicles (EVs) is crucial for understanding their functions. However, it remains challenging to precisely distinguish the characteristics of EVs in specific membrane regions. Herein, we developed a biological optical nanocavity-coupled electrochemiluminescence (ECL) sensor to reveal the correlation between the glycoprotein and membrane curvature of EVs. A curvature-sensitive peptide probe anchored the high curvature membrane of EVs and conducted the proximity ligation with aptamers, enabling the region-specific recognition. By assembling Au NPs onto the membrane surface of EVs, a biological optical nanocavity was constructed, which provided a plasmon coupling effect to enhance the ECL intensity and regulate the polarized emission. The polarized ECL response clearly distinguished both the specific region and molecular distribution of EVs. Our findings indicated that MUC1 with terminal sialylation exhibited preferential distribution in high curvature regions of EV membranes. Furthermore, the detection of EVs in ascites facilitated the diagnosis of peritoneal metastasis in gastric cancer. The proposed ECL sensor achieved sensitive EVs detection with a limit of detection of 3.2 × 103 particles mL-1 and the diagnostic accuracy of 95%. Overall, the research provided a sensitive strategy for the analysis of EVs' membrane nano-environment and explored the potential of EVs in assisting clinical diagnosis.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Stomach NeoplasmsLuminescent MeasurementsElectrochemical TechniquesExtracellular VesiclesBiosensing TechniquesHumansGlycosylationGoldMucin-1Metal NanoparticlesLimit of Detection

Stichwörter der Autor:innen

biological optical nanocavityelectrochemiluminescenceextracellular vesiclesgastric cancer diagnosissurface plasmon coupling

Substanzen

GoldMucin-1MUC1 protein, human

Autor:innen und Institutionen

  • Department of Analytical Chemistry, College of Chemistry, Jilin University, Changchun 130012, China.

ORCID-Profile: Qiang Ma

Förderung

  • National Natural Science Foundation of China
  • Education Department of Jilin Province

Zitieren

APA

Wang, P., Li, Z., Li, W., Ji, F., & Ma, Q. (2026). Biological Optical Nanocavity-Coupled Electrochemiluminescence Sensor for the Detection of Extracellular Vesicle Glycosylation in Gastric Cancer Diagnosis. ACS Sensors. https://doi.org/10.1021/acssensors.6c00361

Vancouver

Wang P, Li Z, Li W, Ji F, Ma Q. Biological Optical Nanocavity-Coupled Electrochemiluminescence Sensor for the Detection of Extracellular Vesicle Glycosylation in Gastric Cancer Diagnosis. ACS Sensors. 2026. doi:10.1021/acssensors.6c00361

BibTeX
@article{Wang2026,
  author = {Wang, Peilin and Li, Zhenrun and Li, Wenyan and Ji, Fangyan and Ma, Qiang},
  title = {Biological Optical Nanocavity-Coupled Electrochemiluminescence Sensor for the Detection of Extracellular Vesicle Glycosylation in Gastric Cancer Diagnosis},
  journal = {ACS Sensors},
  year = {2026},
  doi = {10.1021/acssensors.6c00361}
}
Kostenlos starten →