Nonmagnetic Biomarker Detection by Nanocatalytic-Amplified Quantum Spin Relaxometry
ACS Nano · 16.09.2025 · 19 (36) · 32460-32470
DOI: 10.1021/acsnano.5c08932 ↗Kurz gefasst
Fachartikel in der Zeitschrift ACS Nano, online erschienen am 03.09.2025. Verfasst von Min Wu und 2 weiteren Autor:innen. Beteiligte Einrichtung: School of Mechanical Engineering, Southeast University, Nanjing 211189, People's Republic of China. Hauptthemen laut MEDLINE: Monophenol Monooxygenase, Biosensing Techniques, Biomarkers, Tumor, Nanodiamonds. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 61 Literaturangaben. Gefördert von: Natural Science Foundation of Jiangsu Province, National Natural Science Foundation of China.
Abstract (Originalsprache)
Nitrogen-vacancy (NV) centers in diamond demonstrate advantages in biosensing due to their exceptional photostability and long spin coherence time. However, clinical applications of NV centers are significantly limited because their spin states lack responsiveness to nonmagnetic biomolecules. This work presents a nanocatalytic-amplified quantum sensing platform targeting tyrosinase (TYR), a key biomarker for melanoma. The platform achieves ultrasensitive detection of nonmagnetic biomarkers through nanocatalytic signal transduction. Specifically, we develop plasmonic nanodiamond (FND@Au-Ag) functionalized hydrogel microneedles. The captured TYR triggers a cascade reaction that induces the nanocatalytic generation of hydroxyl radicals (•OH), thereby establishing an AND logic gate based on the dynamic response mechanism of spin relaxation time (T1). By integrating three-modal signals (fluorescence, colorimetry, and T1), the platform achieves a wide dynamic detection range of 0.01-200 U/mL and an ultralow detection limit (0.003 U/mL) for TYR. Ultimately, a genetic algorithm-optimized backpropagation neural network is developed to enhance the reliability of concentration prediction in complex biological matrices. This work proposes an approach to minimally invasive melanoma screening, overcoming the inherent limitations of traditional quantum sensing systems in detecting nonmagnetic biomarkers.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- School of Mechanical Engineering, Southeast University, Nanjing 211189, People's Republic of China.
- School of Automation, Nanjing University of Information Science and Technology, Nanjing 211189, People's Republic of China.
ORCID-Profile: Min Wu, Songlong Jiao, Lei Liu
Förderung
- Natural Science Foundation of Jiangsu Province
- National Natural Science Foundation of China
Zitieren
APA
Wu, M., Jiao, S., & Liu, L. (2025). Nonmagnetic Biomarker Detection by Nanocatalytic-Amplified Quantum Spin Relaxometry. ACS Nano, 19(36), 32460-32470. https://doi.org/10.1021/acsnano.5c08932
Vancouver
Wu M, Jiao S, Liu L. Nonmagnetic Biomarker Detection by Nanocatalytic-Amplified Quantum Spin Relaxometry. ACS Nano. 2025;19(36):32460-32470. doi:10.1021/acsnano.5c08932
BibTeX
@article{Wu2025,
author = {Wu, Min and Jiao, Songlong and Liu, Lei},
title = {Nonmagnetic Biomarker Detection by Nanocatalytic-Amplified Quantum Spin Relaxometry},
journal = {ACS Nano},
year = {2025},
volume = {19},
number = {36},
pages = {32460--32470},
doi = {10.1021/acsnano.5c08932}
}
EUVIMED